4.6.1 Opening
1) Press tool into the right hand hole until the catch loosens
2) Hold the tool pressed in and carefully raise the cover plate
3) Repeat the process on the left hand hole
4) Now carefully lift off the cover plate
/
5) Remove bar handle and drive shaft (square end)
/
6) Replace cover plate (without bar handle) and engage
7)
Insert key and turn clockwise until stop position reached
(key cannot be removed)
If the code needs to be changed, proceed as follows. A penalty time has to elapse be-
fore a new primary code can be programmed in.
8) Press
ON
9) Press
P
10) Press
P
11) Press
0
1 x
12) Press
ON
13) Press
P
14) Enter new 6-digit primary code
15) Enter new 6-digit primary code again
1 x
If the new code as per 15) was incorrectly confi rmed, the signal 3 x
appears.
Repeat the sequence.
By pressing the key combination
P
and
0
all the functions programmed (secondary code,
dual code, time delay, opening window) are deleted.