![Kaba Mas Low Profile 52 series Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/kaba-mas/low-profile-52-series/low-profile-52-series_installation-manual_649094003.webp)
1
I
NTRODUCTION
You should read all instructions carefully before you install and use your Low
Profile 52 Series lock. This will help you avoid unnecessary costs and
concerns resulting from improper installation.
These installation instructions apply to all Low Profile 52 Series Models (Self
Powered and Battery).
Design Parameters for Locks
1.
Bolt dimensions (nominal): .312 inches X 1.000 inches / 8 X 25,4 mm
2.
Bolt movement (nominal) : .465 inches /11,8 mm
3.
Maximum load movable by the bolt: 2,5 N
4.
Maximum load against bolt when thrown (all directions): 1kN (maximum)
5.
The lock can be fitted to safes or vault doors of any material.
Prepare for New Installation of the Lock
1.
Use the template to establish the exact locations (relative to the spindle
hole) of the mounting holes for the lock assembly.
2.
The lock case mounting screws (1/4-20) require drilled and tapped holes to
3/8” depth if possible (minimum 1/4” depth required).
3.
The spindle hole diameter for spindled installation must be a minimum of
3/8” (9.525mm). The maximum spindle hole diameter
of
13/32 inch
(10.32mm) is also the recommended diameter.
4.
Deburr the spindle hole, ensuring that there are no sharp edges that could
cut the cable.
5.
The dial assembly mounting screws (8-32) require drilled and tapped holes
to 3/8” depth if possible (minimum 1/4” depth required).