Kaba Mas CDX-10 Скачать руководство пользователя страница 5

(P/N) 541.1212 Rev B 07/15 • © copyright 2012-2015 

 

Kaba Mas LLC

 

Page 5 of 12

TO OPEN THE CDX-10 FROM THE INSIDE
1. Turn the release knob to the left (counterclockwise) to withdraw the dead bolt. 

LIFE SAFETY OPERATION
The Life Safety Feature (Bolt Stop Assembly) is provided to prevent someone from 
unintentionally extending the lock bolt. 

TO ACTIVATE THE LIFE SAFETY FEATURE
1. Turn the dial to the right (clockwise) to withdraw the lock bolt and also the dead 
  bolt (Extension Bolt).

NOTE: The life safety switch can only be depressed while the lock bolt is 
withdrawn.

2. Depress the life safety switch, located by the LIFE SAFETY label on the dead bolt, 
  until it latches.

ATTENTION: To ensure engagement of the life safety switch, fully rotate the 
release knob counterclockwise and hold in that position. Then depress the life 
safety switch.

Once the Life Safety Feature is activated, the life safety switch blocks the lock bolt 
and prevents the dead bolt from latching when the door is closed.

TO DEACTIVATE THE LIFE SAFETY FEATURE
1. Pull the life safety switch outward to release the bolt stop.

Содержание CDX-10

Страница 1: ...CDX 10 Please read all instructions carefully before putting your CDX 10 into operation INSTALLATION OPERATING INSTRUCTIONS...

Страница 2: ......

Страница 3: ...FROM OUTSIDE 4 TO OPEN FROM INSIDE 5 LIFE SAFETY OPERATION 5 CDX 10 INSTALLATION 6 BASIC TOOLS NEEDED 6 INSTALLATION KIT CONTENTS 7 CDX 10 PARTS FOR INSTALLATION 8 STRIKE INSTALLATION 9 TEMPLATE 9 DE...

Страница 4: ...X 10 Type 1F Lock P N 539 0512 which is enclosed in this Operating Installation Instruction Kit Please refer also to the Model CDX 10 Lock System drawing P N 524 021 for lock nomenclature which is al...

Страница 5: ...lso the dead bolt Extension Bolt NOTE The life safety switch can only be depressed while the lock bolt is withdrawn 2 Depress the life safety switch located by the LIFE SAFETY label on the dead bolt u...

Страница 6: ...stallation BASIC TOOLS NEEDED 1 Medium Phillip s screwdriver 1 2 2 Standard hacksaw 32 teeth inch 3 Small flat file 4 Small vise or a Port A Vise Harbor Freight P4742 5 Drill bits No 25 11 32 1 2 6 El...

Страница 7: ...sing 10 Lubricant Lubriplate 11 Dial Hub Locating Gauge 12 Hex Key 5 64 13 Spindle Screw The Zebra Connector and Zebra Connector Housing are assembled at the factory but may come apart during shipment...

Страница 8: ...PARTS FOR INSTALLATION 1 CDX 10 Dead bolt lock assembly 2 CDX 10 Base hardplate 3 Dial hub assembly 4 Strike Kit 1 of 4 Types 1 2 3 or 9 Strike 9 is shown in photo with screws 5 Spindle 6 Dial ring as...

Страница 9: ...e the template to the door 3 Center punch all hole positions onto the door 4 Drill the 1 2 diameter spindle hole through the door 5 Drill the two 2 CDX 10 attaching screw holes nearest the strike open...

Страница 10: ...LECTRONIC LOCK booklet for additional dial ring installation instructions CUSTOM CUTTING TUBES AND SPINDLE 1 Refer to the sections for cutting tubes and for cutting the spindle in the INSTALLATION INS...

Страница 11: ......

Страница 12: ...not be liable for technical errors or omissions contained herein nor for incidental or consequential damages resulting from the furnishing performance or use of this material 2012 2015 Kaba Mas X 10...

Отзывы: