42
To set a time window, complete the following steps:
Note:
There can be some drifting in the lock clocks in the Model 400
and 500 locks, up to 15 minutes per year. Because of this
possible variance, there should be minor allowances made in
both the starting time and the ending time when setting time
windows
1.
For a PowerStar version of the lock, power the lock by briskly turning
the dial back and forth in both directions.
2.
Press
Enter, Enter
and then
3
. Simultaneous green and red flashes
display.
3.
Enter the Master User Combination. Simultaneous green and red
flashes display.
4.
Enter the two-digit number that represents the day/window code for the
Time Window to be set. Simultaneous green and red flashes display.
5.
Enter the two-digit number that represents the day/window code again
for verification. Simultaneous green and red flashes display.
6.
Enter the two-digit number that represents the starting hour (00-23) for
the Time Window. Simultaneous green and red flashes display.
7.
Enter the two-digit number that represents the starting hour again for
verification. Simultaneous green and red flashes display.
8.
Enter the two-digit number that represents the starting minute (00-59)
within the hour for the Time Window. Simultaneous green and red
flashes display.
9.
Enter the two-digit number that represents the starting minute within
the hour again for verification. Simultaneous green and red flashes
display.
10. Enter the two-digit number that represents the ending hour (00-23) for
the Time Window. Simultaneous green and red flashes display.
11. Enter the two-digit number that represents the ending hour again for
verification. Simultaneous green and red flashes display.
12. Enter the two-digit number that represents the ending minute (00-59)
within the hour for the Time Window. Simultaneous green and red
flashes display.