24
7.
Enter
01
or
02
again to verify the mode you selected in Step 6.
Simultaneous green and red flashes display.
8.
Enter a two-digit number (01-99) to identify the lock in all audit records.
If you do not want to assign an identification number to the lock, enter
00
. Simultaneous green and red flashes display.
9.
If you entered a two-digit number other than “00” in Step 8, enter the
number again for verification. Simultaneous green and red flashes
display.
Set Delay Time and Delayed Opening Window
Note:
Only the Master User can set the delay time and delayed
opening window. The delay time settings can be changed at
any time.
Note:
A change in delayed opening will not take effect until the next
opening.
This operation allows the Master User to define a delay time for opening of
the lock as well as a delayed opening window. The delay time for opening
is the amount of time that must expire before the lock can be opened. The
Master User can specify a time period of 05-99 minutes for Models 100,
200, and 400 or 01-99 minutes for a Model 500. This delay period begins
as soon as a single valid combination is entered. In Supervisory/Subordi-
nate mode, a Subordinate user must be enabled before a Subordinate
combination can be entered to begin the time delay period. If you attempt to
enter a combination during a time delay period, the LED will display three
red flashes to indicate an error.