Kaadas Hugolog Z-Wave Plus HU04 Скачать руководство пользователя страница 6

 

Association Group Information (AGI) Command Class* 

V1 

Battery Command Class* 

V1 

Device Reset Locally Command Class* 

V1 

Door Lock Command Class* 

V2 

Firmware Update Meta Data Command Class* 

V4 

Language Command Class* 

V1 

Manufacturer Specific Command Class* 

V2 

Notification Command Class* 

V8 

Power Level Command Class* 

V1 

Security 0 Command Class 

V1 

Security 2 Command Class 

V1 

Supervision Command Class 

V1 

Time Command Class 

V1 

Time Parameters Command Class* 

V1 

Transport Service Command Class 

V2 

User Code Command Class* 

V1 

Version Command Class* 

V3 

Z-Wave Plus Info Command Class 

V2 

Command Class Requires Security S0/S2 

 

Command Class Door Lock, Version 2 

Z-Wave Plus locks only support 2 door lock modes: Door Secured 

(0xFF) and Door Unsecured (0x00) 

Door locks do not support timed operation from the door lock 

command class. 

 

Command Class User Code, Version 1 

The door lock will only retain valid user code types (0x00, 0x01). All 

other values will be ignored. 

Door locks support multiple different user status bytes: 

Содержание Hugolog Z-Wave Plus HU04

Страница 1: ...Z Wave Plus System Integrators Guide Document Revision 1 0...

Страница 2: ...Wave Plus System Integrators Guide 1 Document Revision 1 0 1 About Z Wave 1 Z Wave function descriptions 1 Z Wave Plus Info 3 Supported Command Classes 3 Association Table 5 Notifications Table 5 Z W...

Страница 3: ...ring instruction Exclusion log off is detailed in Programming instruction under Network pairing instruction This lock could be integrate with any Z Wave controller from any manufacturer The lock will...

Страница 4: ...work and add the lock Follow the user guide of hub to enter inclusion mode Operate on lock following guide below Enter master mode Master PIN Code Wait for 2 Green Lights 2 Beeps Input 8 1 to enter In...

Страница 5: ...ing voice guide Please use this procedure only when the network primary controller is missing Default master pin code is 12345678 please modify it after reset Refer to programming instruction Z Wave P...

Страница 6: ...e Command Class V1 Time Parameters Command Class V1 Transport Service Command Class V2 User Code Command Class V1 Version Command Class V3 Z Wave Plus Info Command Class V2 Command Class Requires Secu...

Страница 7: ...state variable has changed state Door Lock Operation Report Issued by a node when it has completed a lock unlock operation initiated locally User Code Report Issued when a user code has changes Devic...

Страница 8: ...IO N 0x06 0x13 User Id Keypad unlock operation LOCK_JAMMED 0x0B 0x00 0x00 Lock jammed ALL_USER_CODES_DEL 0x0C 0x00 0x00 All user codes deleted SINGLE_USER_CODE_DEL 0x0D 0x21 User Id Single user code d...

Отзывы: