Kaadas Hugolog Z-Wave Plus HU04 Скачать руководство пользователя страница 4

 

utilize all implemented functions. This product can be operated in any Z-

Wave network with other Z-Wave certified devices from other 

manufacturers. All non-battery operated nodes within the network will 

act as repeaters regardless of vendor to increase reliability of the 

network. 

 

-Join a network: inclusion Z-Wave network and add the lock. 

 

Follow the user guide of hub to enter inclusion mode. 

 

Operate on lock following guide below: 

 

Enter master mode(** + Master PIN Code + #), Wait for 2 Green 

 2 Beeps 

 

Input “8+1+#” to enter “Inclusion mode” (2 Green  2 

Beeps) 

 

-Log off a network: Exclusion Z-Wave network and remove the lock 

 

Follow the user guide of hub to enter exclusion mode. 

 

Operate on lock following guide below: 

 

Enter master mode(** + Master PIN Code + #), Wait for 2 Green 

 2 Beeps 

 

Input “8+2+#” to enter “Exclusion mode”(2 Green  2 

Beeps) 

 

Содержание Hugolog Z-Wave Plus HU04

Страница 1: ...Z Wave Plus System Integrators Guide Document Revision 1 0...

Страница 2: ...Wave Plus System Integrators Guide 1 Document Revision 1 0 1 About Z Wave 1 Z Wave function descriptions 1 Z Wave Plus Info 3 Supported Command Classes 3 Association Table 5 Notifications Table 5 Z W...

Страница 3: ...ring instruction Exclusion log off is detailed in Programming instruction under Network pairing instruction This lock could be integrate with any Z Wave controller from any manufacturer The lock will...

Страница 4: ...work and add the lock Follow the user guide of hub to enter inclusion mode Operate on lock following guide below Enter master mode Master PIN Code Wait for 2 Green Lights 2 Beeps Input 8 1 to enter In...

Страница 5: ...ing voice guide Please use this procedure only when the network primary controller is missing Default master pin code is 12345678 please modify it after reset Refer to programming instruction Z Wave P...

Страница 6: ...e Command Class V1 Time Parameters Command Class V1 Transport Service Command Class V2 User Code Command Class V1 Version Command Class V3 Z Wave Plus Info Command Class V2 Command Class Requires Secu...

Страница 7: ...state variable has changed state Door Lock Operation Report Issued by a node when it has completed a lock unlock operation initiated locally User Code Report Issued when a user code has changes Devic...

Страница 8: ...IO N 0x06 0x13 User Id Keypad unlock operation LOCK_JAMMED 0x0B 0x00 0x00 Lock jammed ALL_USER_CODES_DEL 0x0C 0x00 0x00 All user codes deleted SINGLE_USER_CODE_DEL 0x0D 0x21 User Id Single user code d...