5.2 Rear Panel
depicts the rear panel of the OptoLyzer MOCCA compact FD.
Figure 5.2 Rear Panel - OptoLyzer MOCCA compact FD
Notes:
The rear panel (
) shows four DE-9 connectors, two on the left side and two in the
middle of the panel. View the red frames above to get an impression which description
belongs to which interface.
describes the connectors of the rear panel from top to bottom and left to right.
Table 5.3 Connectors on the Rear Panel
INTERFACE
DESCRIPTION
High Speed CAN
1/3/5
2/4/6
These two connectors offer six High-Speed CAN instances with baud rates from
33.333 kbit/s to 1 Mbit/s depending on the cable length. The CAN instances 1, 3, 4 and
5 are hard specified as High-Speed CAN interfaces. The CAN instances 2 and 6 can also
be used as CAN FD interfaces. The CAN interfaces can be controlled by a customer
application. Details about the CAN bus properties are described in
. For the pin out refer to
Section 6.1, "High-Speed CAN," on page 22
.
LIN / FlexRay
This DE-9 socket combines pins assigned to the FlexRay bus and pins assigned to the
LIN channels 3, 4, 5 and 6. For the pin out refer to
Section 6.2, "LIN / FlexRay," on
.
LIN
CAN 7/8
This DE-9 socket combines two CAN FD interfaces (CAN instances 7 and 8) as well as
two LIN channels (1 and 2). The CAN interfaces can be controlled by a customer
application. For the pin out refer to