Maintenance

• Remove the fan impeller if it is very dirty.

• Wipe all plastic parts with a soft cloth dampened with a soap solution

Malfunction

Probable cause

Remedy

When connected to the 

power grid, the fan does not 

rotate, does not respond to 

controls.

The mains supply is not connected.

It is necessary to consult a specialist.

Internal connection fault.

Low air flow.

The ventilation system is clogged.

Clean the ventilation system.

Increased noise or vibration.

The impeller is blocked.

Clean the impeller.

The fan is not fixed or incorrectly mounted.

Correct the installation error.

The ventilation system is clogged.

Clean the ventilation system.

Possible problems and solutions

ATTENTION!

The fan and the service controlling equipment has to be isolated from power supply during the installation 

time and service. 

Pic.4 STANDARD

Pic.5 STANDARD-02

Storage and transportation

Keep the fan only in the packaging of the manufacturer in a ventilated room at a temperature of +5 ° C to +40 ° C and relative 

humidity of 80% (at T = 25 ° C). Keeping time - 5 years from date of manufacture. Products transported by any transport 

provided consumer protection or transport container from the direct effects of rainfall, lack of bias transport places during 

transport, the lack of mutual  physical impact during transportation and preservation of fans. Transportation is carried out in 

force with the rules for this transport.

This marking indicates that this product should not be disposed with other household wastes throughout the EU. To

prevent possible harm to the environment or human health

from uncontrolled waste disposal, recycle it responsibly to

promote the sustainable reuse of material resources. To return

your used device, please use the return and collection

systems or contact the retailer where the product was purchased. They

can take this product for environmental safe recycling.

Disposal

Содержание Exklusiv 01

Страница 1: ...Axial duct domestic electric fans Kleinraumventilator Passport Operation instruction Pass Bedienungsanleitung EN DE EN DE...

Страница 2: ...ace with chimney care must be taken to ensure that sufficient air can enter the room being ventilated In rooms with high humidity installation must be done in accordance with DIN VDE 0100 T701 Use a s...

Страница 3: ...80 120 225 90 140 250 100 185 Power consumption W 8 4 10 9 13 16 20 0 05 0 07 14 18 22 14 16 8 4 10 19 20 7 8 10 10 16 20 Noise level dB 25 30 25 30 36 39 25 27 32 34 36 32 33 25 30 36 38 25 30 33 35...

Страница 4: ...180 250 160 230 58 5 7 24 125 180 250 160 230 58 5 8 5 24 This size is present only in fans with back flow valve option Installation and set up procedures The fan can be connected to ventilation duct...

Страница 5: ...ction of Exklusiv fans to the network Connection of fan to the network shown in pic 1 4 remove the decorative front panel hold the power wire through the cable hole 1 in the case strip the insulation...

Страница 6: ...the terminal block cover hold the power wire through the cable hole 1 in the case strip the insulation on 5 7 mm from the wire end insert wires into terminal box X and press them by tap screw fix the...

Страница 7: ...nd transportation Keep the fan only in the packaging of the manufacturer in a ventilated room at a temperature of 5 C to 40 C and relative humidity of 80 at T 25 C Keeping time 5 years from date of ma...

Страница 8: ...t badge must be on the fan Make sure your product has this badge and leave it on the product for its entire life Please keep the purchase documents invoice or receipt that confirm the date and time of...

Страница 9: ...hpersonal und entsprechend den jeweils g ltigen Vorschriften erfolgen Spannung und Frequenz der Stromversorgung m ssen mit den Angaben des Ventilators bereinstimmen Installationsseitig ist eine allpol...

Страница 10: ...4 10 9 13 16 20 0 05 0 07 14 18 22 14 16 8 4 10 19 20 7 8 10 10 16 20 Ger uschpegel dB 25 30 25 30 36 39 25 27 32 34 36 32 33 25 30 36 38 25 30 33 35 36 Gewicht kg 0 5 0 7 0 53 0 7 0 53 0 7 0 6 0 75...

Страница 11: ...5 9 150 205 205 187 187 86 10 9 100 180 250 160 230 58 5 7 24 125 180 250 160 230 58 5 8 5 24 Vorbereitung f r Montage und Inbetriebnahme Der L fter kann an L ftungsrohre angeschlossen werden Das Ger...

Страница 12: ...schlie en der L fter der Exklusiv Serie an das Netzwerk Die Vorgehensweise zum Anschlie en des L fters an das Stromnetz ist in den Abbildungen 1 4 dargestellt Abbildung 1 Exklusiv 01 2 1 Entfernen Sie...

Страница 13: ...rahtisolierung F hren Sie die Dr hte in die Klemmenleiste X ein und befestigen Sie diese Sichern Sie die Dr hte mit der Klemme 2 Abbildung 4 Montieren Sie die Sockelf e F hren Sie eine Abdeckungsh lft...

Страница 14: ...en M gliche Probleme und M glichkeiten sie zu beseitigen ACHTUNG Ventilator vor der Montage und oder Wartung von der Stromversorgung trennen M gliche L sung Lagerbedingungen Der L fter sollte nur in d...

Страница 15: ...ich auf dem Ventilator befinden Stellen Sie sicher dass Ihr Produkt ber diese Plakette verf gt und lassen Sie sie w hrend der gesamten Lebensdauer auf dem Produkt Bitte bewahren Sie die Kaufdokumente...

Страница 16: ...____ Mark of Quality Department _____________________________ Approval certificate The fan is recognized suitable for operation Exklusiv 01 100 Exklusiv 01 125 No options 02 TURBO ET HT ETF MT MR MRH...

Отзывы: