![K-Rain 3506 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/k-rain/3506/3506_instruction-manual_648535014.webp)
12
OTHER FEATURES
FITTING A RAIN SENSOR (OPTIONAL)
A rain sensor can be wired directly into the terminal block. When the
sensor is wet, all
automatic
and
manual
watering will not operate.
To fit a rain sensor follow this procedure:
1. The sensor switch, accessed on the
fascia, must be up in the “ON” position. To
over-ride the sensor when it is wet, simply
move the sensor switch down to the
“OFF”
position. This will allow automatic and
manual watering cycles to operate.
2. Connecting the rain sensor wires:
A.
Remove the link connector by loosening both screws
and slide out. (Link located under the terminal cover.)
B.
Run the new sensor
wires into the terminal
block and replace where
the link was. Fasten one
wire under the common
(C), the other into the
24VAC. Polarity not
applicable.
New Sensor wires
NOTE:
Far left 24VAC Terminal is active.
TIP:
It is important to move the sensor switch back to the “ON” position
after completing your watering cycle.
Remove link connector
Содержание 3506