K-Rain 3506 Скачать руководство пользователя страница 1

INSTRUCTION MANUAL

www.krain.com

STATION MODELS

 - Available in 4 OR 6 stations.

OUTDOOR MODEL

 -  Supplied with 120VAC x 24VAC inbuilt transformer.  

OPTIONAL LEAD WITH PLUG.

MINI IRRIGATION CONTROLLER

Содержание 3506

Страница 1: ...INSTRUCTION MANUAL www krain com STATION MODELS Available in 4 OR 6 stations OUTDOOR MODEL Supplied with 120VAC x 24VAC inbuilt transformer OPTIONAL LEAD WITH PLUG MINI IRRIGATION CONTROLLER ...

Страница 2: ...y Run A Single Station Run A Program OTHER FEATURES Stop Stacking Start Times Automatic BackUp Program Fitting a Rain Sensor Optional Rain Off Mode Water Budgeting INSTALLATION INSTRUCTIONS Mounting The Controller Electrical Hook Up Field Wiring Connections Terminal Block Layout Power Supply Connections Connection Of Valves Pump Hook Up Connections ELECTRICAL CHARACTERISTICS SERVICING THE CONTROLL...

Страница 3: ... the same program as they need to be watered on the same days These stations valves will water in sequential order from the lowest number at the start time or times nominated and on the days selected Maximum watering duration for a station valve is 12 hours and 59 minutes This controller has three types of watering day options Either interval watering from everyday to every 15th day individual day...

Страница 4: ...CH Manually activate rain sensor by switching to ON OFF position PROGRAMMING BUTTONS Used for adjusting the programmed information INDOOR CONTROLLER MODEL TERMINAL COVER Remove to access terminals for solenoid valve wires and to annually replace 9 volt block battery FUSE LOCATION Remove cover to access fuse ...

Страница 5: ...en areas which have similiar watering requirements Examples are Turf Areas Flower Beds Pergola Undercover Areas or Vegetables These different groups require individual settings 2 Planning out your watering program Complete your individual watering planner supplied at the back of this book 3 Setting the current time and correct day of the week 4 Setting an automatic program start Use the following ...

Страница 6: ...GRAMMING Tips to help eliminate programming confusion Complete the spare watering planner When setting one push of the button will increment one unit Holding one button down will fast scroll through units During programming only the flashing values are able to be set use the or buttons Pressing will scroll forward through the settings in an orderly sequence Pressing will scroll back to previous set...

Страница 7: ...DD EVEN day watering in areas where water restrictions may require this feature Press button until the year month day are shown The year will be flashing Use or to adjust Press button and the month will flash Use or to adjust Press and the day will flash Use or to adjust TIP To return to the clock Press or turn dial to another position Before proceeding ensure your watering planner has been completed...

Страница 8: ... to adjust NOTE AM PM is set correctly Press the minutes will flash Use or to adjust if required Each program has up to four start times and should you require a second start time Press twice Start 1 will flash Advance to start 2 by pressing THE DISPLAY WILL SHOW Press and proceed as per setting Start 1 TIP To turn an active start time off turn the dial to the Set Start times position select the sta...

Страница 9: ...n Examples Interval 2 means watering will take place every second day 3 means watering will be every third day etc Interval watering can be set from everyday to every 15th day The Run Day refers to the number of days press the next watering program will occur INDIVIDUAL DAY SELECTION Press the button This is the selectable day option THE DISPLAY WILL SHOW This refers to Mon being Day 1 To turn Mon...

Страница 10: ...N will be shown This feature may be required in areas where water restrictions are enforced NOTE Remember to set the 365 day calendar when setting the clock or this feature will be out of sequence STEP 3 Set Station Run Times This is the length of time that each station valve is set to water on a particular program Maximum watering time is 12 hours 59 minutes for each station A station can be assi...

Страница 11: ...set to OFF Remember all stations are set at a default run time of 10 minutes in Program 1 NOTE To set a station to OFF Use when the RUN TIME is flashing This completes the setting up procedure for automatic watering of Program 1 Should you need a second program Turn the dial to Set Start Times and Prog 1 will flash press and change to program 2 position and follow the same 3 steps to set an automati...

Страница 12: ...e new default time TIP If the water supply is from a pump system it is critical to ensure all outputs are connected to a valve Any output NOT connected to a valve should be linked back with a wire to the nearest output with a valve This prevents the pump running against a closed head RUN A SINGLE STATION Turn the dial to Run Single Station There will be a two second pause To adjust the run time us...

Страница 13: ...RT TIMES Should you accidently set the same watering start time on more than one program the controller will stack them in sequential order from the lowest number All programmed start times will be watered but the start times will be shunted along AUTOMATIC BACK UP PROGRAM When the battery is not fitted or is low there is a backup default program in program 1 watering every day at 12 00 a m for 10 ...

Страница 14: ...to the OFF position This will allow automatic and manual watering cycles to operate 2 Connecting the rain sensor wires A Remove the link connector by loosening both screws and slide out Link located under the terminal cover B Run the new sensor wires into the terminal block and replace where the link was Fasten one wire under the common C the other into the 24VAC Polarity not applicable New Sensor...

Страница 15: ...the seasons change This will save time and money as the run times can be adjusted quickly in spring winter and autumn to reduce the amount of water used Ensure that the dial is in the Auto Run position and then press the button THE DISPLAY WILL SHOW Displayed is the word Budget and 100 This represents the current automatic watering run times as being 100 The percentage budget can be set in 25 incr...

Страница 16: ...y use a toggle bolt or masonary shield Hang the controller from the key slot located in the back of the case Make sure the head is properly seated inside the controller case Additional screws may be inserted through the holes in the lower corners of the controller case ELECTRICAL HOOK UP WARNING 1 All electrical work must be carried out in accordance with these instructions following all applicabl...

Страница 17: ...ripped wire ends into the clamp aperture and tighten screws Do not over tighten as this may damage the terminal block 3 A maximum of 0 5 Amps may be supplied by any output Check the inrush current of your solenoid coils before connecting more than two valves to any one station TERMINAL BLOCK LAYOUT THE TERMINAL BLOCK IS LAID OUT AS FOLLOWS INSTALLATION INSTRUCTIONS GLOSSARY 24VAC 24VAC Power Suppl...

Страница 18: ...ed to a 120VAC supply which is also servicing or supplying motors i e Air conditioners pool pumps refrigerators etc Lighting circuits are suitable as a power source CONNECTIONS TO THE UNIT ARE AS FOLLOWS CONNECTION OF VALVES Up to two 24VAC Solenoid Valves can be connected to each station output and wired back to the common C thus Valve wires enter the controller through the rear ...

Страница 19: ...t of the controller and the other side to the controller common For systems supplied with water from a pump unused stations must be connected back to the last used station to eliminate the possibilty of the pump running against a closed head Failure to do so could lead to pump damage The diagram shows an 6 station controller with 4 active stations valves Unused stations must be linked back to the ...

Страница 20: ... ELECTRICAL OUTPUTS ELECTRICAL POWER SUPPLY Input 24Volts AC 60Hz Electrical Outputs Maximum of 0 85 AMPS To Solenoid Valves 24 VAC 50 60 Hz 0 5 AMPs max To the Master Valve Pump Start 24VAC 0 25 AMPs maximum NOTE Transformer and fuse capacity must be compatible with output requirements Overload protection Standard 20mm 1 Amp fuse Power failure 9 Volt battery maintains clock and programs for up to...

Страница 21: ...k to the controller maintaining your valve watering sequence 4 Disconnect valve wires from the terminal block 5 Remove the complete unit from the wall 6 Carefully wrap the complete unit in protective wrapping and pack in a suitable box Return to your service agent or the manufacturer NOTE Tampering with the unit will cancel the Guarantee 7 Replace your controller by reversing this procedure SERVIC...

Страница 22: ... Swap faulty station wire on controller terminal block with known working station wire If the faulty valve still does not work on the known working connection then the solenoid coil is faulty The panel may need to be repaired Check wiring and connections If unit works manually check programming Check fuse and field wiring Check instruction book to ensure programming correct If keypad still not resp...

Страница 23: ...21 SPARE WATERING PLANNER ...

Страница 24: ...22 NOTES ...

Страница 25: ...23 NOTES ...

Страница 26: ...t The guarantee shall not apply to any equipment which is found to have been improperly installed set up or used in any way not in accordance with the instructions supplied with this equipment or to have been modified repaired or altered in any way without the express written consent of the company This guarantee shall not apply to any batteries or accessories used in the equipment covered under th...