III. PROBLEM

   Controller does not turn ON in manual mode.

 CAUSE: 

No power to controller.

 SOLUTION:  Be sure that controller is properly wired as per Electrical Circuit and  

Connection Diagram.

 SOLUTION:  Check circuit breaker.

IV. PROBLEM

   Controller fails to operate properly in automatic (AUTO) mode. 

 CAUSE: 

Day Wheel not properly programmed.

 SOLUTION:  Check Setting and Operation Instructions for programming day wheel. 
 CAUSE: 

Auto-Off-On knob not set properly.

 SOLUTION:  Turn Auto-Off-On knob to auto position.
 CAUSE: 

Switch adjustment needed. 

 SOLUTION:  Remove controller face from enclosure after disconnecting power to unit. 

The switch adjustment screw is located on the switch cover. A clicking of 

the switch should be heard when the switch arm is slowly pulled back at 

the halfway point between the edge of the time dial and the far edge of the 

timing pin. With a small screwdriver, tighten the screw clockwise to cause 

the switch to activate sooner. If switch is activating sooner than desired,  

turn adjustment screw counter-clockwise slightly.

 CAUSE: 

Switch contacts or relay worn out.

 SOLUTION:  Replace switch or relay (see parts list), ensuring that the controller is  

properly rewired. NOTE: A nut driver tool is available to assist in removing 

black retainer nuts. 

Should the above troubleshooting tips fail to correct the problem you may be having,  

please consult your local K-Rain

®

 distributor for service or replacement.

Содержание 2000 Series

Страница 1: ...2000 Series Single Station Controller Instruction Manual ...

Страница 2: ...ontroller will operate in AUTO only on the days programmed by the depression of the day wheel pin Once properly set correct day is shown by the alignment of the arrow labeled DAY with the day shown on the day wheel 3 Auto Off On Switch Knob Indicates the function of the controller by turning to ON for manual operation AUTO for automatic operation and OFF to stop manual ON and automatic AUTO functi...

Страница 3: ...02 A U T O TIM E D A Y O N O F F 4 5 Time Dial Day Wheel and Retained Pin Assembly Chassis Screws Auto Off On Switch Knob Electrical Connection Strip 1 3 2 ...

Страница 4: ... with pins should be pulled out gently TO SET OPERATING TIMES The 24 hour Time Dial has ninety six 15 minute increments The timing pins should be inserted in the Time Dial to indicate the desired operating times Included with each controller is a package of white 15 minute pins Longer timing periods may be obtained by placing white pins directly next to each other in Time Dial Also available are s...

Страница 5: ...local code When making wire connections do not pull excessively on controller wires as they can become disconnected Properly ground controller When reinstalling controller face or lower cover do not trap wires between standoffs and screws Remove lower cover on controller face Make wire connections to electrical connection strip as indicated by Electrical Circuit and Connection Diagram Reinstall lo...

Страница 6: ... Pilot Valve Valve Dump SWITCH LOAD LINE IN CLOCK MOTOR 120 VAC Model 2110 Model 2116 Models 2112 2120 Models 2114 22 SWITCH LOAD LINE IN CLOCK MOTOR RELAY SWITC LINE IN CLOCK MOTOR RE TRANSFORM In Out Ground Ground In G Pilot Valve Valve Dump SWITCH LOAD LINE IN CLOCK MOTOR 120 VAC Model 2116 LINE IN CLOC MOT ...

Страница 7: ...CLOCK MOTOR RELAY SWITCH TRANSFORMER LINE IN CLOCK MOTOR RELAY TRANSFORMER Power Out Power In Power Out Ground Power In Power Out e Dump LOAD R 120 VAC Models 2112 2120 Models 2114 2214 2124 SWITCH LOAD LOAD LINE IN CLOCK MOTOR RELAY SWITCH TRANSFORMER LINE IN CLOCK MOTOR RELAY TRANSFORMER Models 2114 2124 2214 Models 2112 2120 2210 ...

Страница 8: ...CONTROLLER DIAGRAM 07 ...

Страница 9: ...iming pins 18 1009955 7 minute yellow timing pins 18 1009956 3 minute orange timing pins 18 1009957 Mixed assortment of timing pins 6 each 1009947 15 hour black timing pins 6 1009959 10 14 day retained pin set for day wheel 1000114 OTHER COMPONENTS Relay 110 VAC 60 Hz coil double throw single pole 2 HP 1320110 Relay 220 VAC 60 Hz coil double throw single pole 2 HP 1320220 Transformer 110 VAC input...

Страница 10: ...spect drive gear Install new drive gear noting this side out Reinstall time dial and be sure it turns freely clockwise II PROBLEM Controller improperly staying ON CAUSE Switch is being activated SOLUTION Ensure that wires do not push against switch or relay Ensure that wires leading to switch are not pulled out CAUSE Controller improperly wired SOLUTION Check Electrical Circuit and Connection Diag...

Страница 11: ...r to unit The switch adjustment screw is located on the switch cover A clicking of the switch should be heard when the switch arm is slowly pulled back at the halfway point between the edge of the time dial and the far edge of the timing pin With a small screwdriver tighten the screw clockwise to cause the switch to activate sooner If switch is activating sooner than desired turn adjustment screw ...

Страница 12: ...ns may not apply to you If a defect arises in a K Rain product within the two year warranty period you should promptly contact your K Rain installer distributor or K Rain Manufacturing Corporation at 1640 Australian Avenue Riviera Beach Florida 33404 Please allow up to 4 weeks for completion of repairs or replacement and return of the product If a product is replaced the replacement product is cov...

Отзывы: