Alarm setting
Select
Setting
from the menu, then
select
Alarm
.
This operation sets the operations that the VN-A1U executes upon receipt of
the four kinds of alarm signals.
With [MotionDetection Alarm], [Alarm 1] and [Alarm 2], the operations
to be executed upon reception of the three kinds of alarm signals
from the VN-A1U can be set by checking the following checkboxes.
There are four functions as follows:
• Message
Pop-up the message entered in the text box.
(There is a limit on how many characters that can be displayed.)
• Recording
Start recording the images.
• Playing wave file
Play a specified wave file . Any wave files can be specified from the
Browse button.
• Execute application file
Execute a specified application file. Any execute (.exe) files can be
specified from the Browse button.
Select Non-Stop or Stop in 1
minute after the recording starts,
Stop in 1 minute is used for saving
space on the hard disk.
W h e n S t o p i n 1 m i n u t e i s
s e l e c t e d , n o r m a l r e c o r d i n g
s p e c i f i e d o n t h e c o n t r o l l e r
software also stops in 1 minute
after the alarm is received.