16
1. Connecting to the network
• Turn on the power of only one VN-A1U unit.
When network connection is completed and the power is turned on, the
VN-A1U unit will be connected to the network at the following IP address.
Factory default IP address:
192.
168.
0.
2
* Use a straight cable when connect-
ing to a HUB. Use a cross cable when
connecting directly to a PC.
●
About the power supply connection cable
• Length: Should be 30 m (98 feet) or less.
• Recommended cable type: UL1007, UL1015 or equivalent
cable with a power capacity higher or equivalent to an AWG#20.
Setup
10 BASE-T
CAT-5 Cable
Power supply (DC 12 V or
AC 24 V 50 Hz/60 Hz)
FOR EUROPE
ISOLATED POWER ONLY
CLASS 2 ONLY FOR USA
–
+
Power Supply
CAUTION
When shipped from the factory, the IP address of all VN-A1U units is set to
192.168.0.2 Consequently, if multiple units are installed in the same LAN
environment and the power is turned ON at the same time, duplication of IP
addresses will occur and correct access will not be possible. Always turn the
power on for only one unit at a time. Once duplication of IP addresses has occurred
(and after confirming that only one VN-A1U exists in the same LAN environment),
wait a while (10 minutes or longer), or turn off the power of all the network devices
on the same LAN environment, before turning the power ON again. If this is not
done, it may not be possible to access the VN-A1U.
Содержание VN-A1U - Network Encoder
Страница 64: ...64 204 189 189 185 47 44 Dimensions Unit mm ...