4
Measuring
Measuring point (
*
)
No.
Item
instruments &
Adjustment parts (
-
)
Adjustment procedure
Input signals
Adjustment level (
+
)
1
12V supply
voltage check
• Digital voltmeter
1) Check to see if the specified voltage is meas-
ured at the measuring point.
*
Between pin 5 of CN1 and
GND [MAIN]
+
+12V ± 0.5V
2.3 CHECK OF SUPPLY VOLTAGE
1
H. HOLD
adjustment
• Frequency
counter
1) Adjust VR3 to obtain the specified frequency
at the measuring point.
*
Between collector of Q10
[MAIN] and TP3(GND)[VR]
-
H. HOLD(VR3)[MAIN]
+
14.7 ± 0.3kHz
2.4 ADJUSTMENT OF H.HOLD
1
V.HOLD
adjustment
• Oscilloscope
(V-rate,10:1)
1) Adjust VR5 to obtain the specified level at the
measuring point.
*
TP2 and TP3 (GND)[VR]
-
V. HOLD(VR5)[MAIN]
+
17.5 ± 0.5ms(U.Ver)
+
21 ± 0.5ms(E.Ver)
2.5 ADJUSTMENT OF V.HOLD
1
Video level
adjustment
• Gray scale chart
• Oscilloscope
(H-rate,10:1)
1) Shoot the gray(scale) chart by the camera.
2) Observing the waveform on oscilloscope, ad-
just VR101 to obtain the specified level at the
measuring point.
*
TP1[MAIN] and TP3
(GND)[VR]
-
VIDEO LEVEL(VR101)
[MAIN]
+
+10 ± 0.5V DC
2.6 ADJUSTMENT OF VIDEO LEVEL
17.5
±
0.5ms(U.Ver)
21
±
0.5ms(E.Ver)
+10
±
0.5V DC
0V DC