39
Troubleshooting
OTHERS
Symptom
Remedy
The operation becomes un-
stable
The auto iris will not operate
There is noise in the screen
or increase in residual images
The colors of the screen are
not natural
White balance adjusted
automatically/manually
cannot be used
The camera title will not ap-
pear
The vertical phase cannot be
adjusted using the V PHASE
menu item
Drop in voltage of the power supply can
be considered. Check the length and thick-
ness of the power supply cable.
(
Page 17)
Set the VIDEO/DC switch on the side of
unit according to the type of auto iris lens
used.
(
Pages 20, 21)
Lower the gain using the AGC MODE
menu item.
SUPER HIGH LOW OFF
(MAX)
(MIN)
Gain
(
Page 29)
When using in an environment where there
are changes in the light source, set the
WHITE BALANCE menu item to ATW.
(
Page 32)
Set the WHITE BALANCE menu item to
AWB or MANUAL.
(
Page 32)
Set the CAMERA TITLE menu item to ON.
(
Page 35)
When adjusting the vertical phase during
line lock, set the LL/INT switch on the back
of unit to LL.
(
Page 35)