Use twisted-pair cables for the connections.
●
Duplex
When the camera is controlled using the full duplex proto-
col, set Switch 5 to OFF.
●
Simplex
When the camera is controlled using the simplex trans-
mission protocol, set Switch 5 to ON.
Camera
Controller
RX+
RX–
TX+
TX–
TX+
TX–
RX+
RX–
Camera
Controller
RX+
RX–
TX+
TX–
Two wires must be connected.
Four wires must be connected.
For example (connection with an RM-P2580)
Camera
RM-P2580
RX+ C
RX– D
C TX+
D TX–
TX+ A
TX– B
A RX+
B RX–