17
Remove the dome cover, followed by setting the
video image switches.
1.
Removing the dome cover
Remove the dome cover by unfastening the 3
fastening screws using the wrench supplied.
Memo:
●
The dome cover and base are connected
with fall prevention wire.
2.
Removing the inner dome
The inner dome is fastened using lugs at 3
different positions. Grasp the inner dome and
remove it from the lugs.
Note:
●
Before touching the camera unit, make sure
to touch the metal surface of the [MONITOR]
terminal to discharge any static electricity
from your body. Static electricity may cause
the camera to malfunction.
3.
Setting the switches
Set the switches for video images.
(
A
Pg. 12)
Remove the camera unit from the base and
mount the base to the ceiling or wall.
When mounting to a wall, follow the procedures by
replacing areas indicated as [ceiling] by [wall] accordingly.
1.
Removing the camera unit from the base
A
Unfasten the 2 fastening screws from the
camera unit using a screwdriver.
B
Press the 2 lugs inwards to remove the
camera unit from the base.
Setting the switches
Wrench (Supplied)
Fall Prevention
Wire
2
3
LL PHASE
1
2
O
N
3
4
5
6
7
2
4
WHT.
BAL.
8
Inner
Dome
Lug(x 3)
Mounting the base
Setup
Drill mounting holes (
R
30 mm, 1 1/8 inch)
using the template supplied when necessary.
Coaxial Cable
Approx. 100 mm
(37/8 inch)
R
30 mm
(1 1/8 inch)
Power Supply Wire
(AC 24 V only when heater is in use)
A
B
Camera
Base
Lug(x 2)
TK-C215VP4_JP.book Page 17 Wednesday, September 20, 2006 5:48 PM
Содержание TK-C215VP12
Страница 35: ...31 Focus chart ...
Страница 36: ... 2006 Victor Company of Japan Limited LST0509 001A TK C215VP4 DOME CAMERA ...