4.2
DVD TEST MODE
Destination VERSION id displayed.
The display to the VERSION code is as follows.
JC / 1U / D / E / 2U / 3U / UB / UT / 4U / UY / EE / UF
Region code display
The study state and an initialization state from a back end are
displayed on the 10th and 11th figure of FL display.
The study state (The 10th figure)
"3" : DVD Study un-completing, CD Study un-completing
"2" : DVD Study completing, CD Study un-completing
"1" : DVD Study un-completing, CD Study completing
"0" : DVD Study completing, CD Study completing
NORMAL initialization
segment of FL is RDS on at the time of the completion of
initialization.
Press the "F.SKIP" key on the main unit
or remote controller for a long time.
Insert the power cord in an outlet while
pressing the "POWER" and "PLAY" keys
on the main unit simultaneously.
FL indication
TEST bb#
Press the "PAUSE" key on the main unit.
FULL initialization
segment of FL is RDS on at the time of the completion of
initialization.
Press the "MENU" key on the remote controller.
FL indication
(For Example) " 1234 "
Display the checksum of a device key on FL. (4byte)
FL indication
eaa cccc
d bb
Display the version of a micom on FL.
aa : SYS, bb : MECHA, cccc : BE
d : MECHACON ROM collection's version
One digit out of two digits is indicated.
e : SYSCON ROM collection's version
One digit out of two digits is indicated.
TEST bb#
The initialization state (The 11th figure)
"3" : FULL initialization end
"0" : NORMAL initialization end
"Blank" : Initialization un-ending
It is made POWER ON in test mode, and VERSION is displayed on FL.
FL indication
TEST bb#
FL indication
TEST bb#
Press the "MENU" key on the remote controller.
1
FL indication
ALL FL light UP
Press the "MENU" key on the remote controller.
Switch on the all-points light of FL and LED.