1-12 (No.MA209)
A
Initialization of user setting data
INITIALIZE
NOW EXECUTING
COMPLETED
CLEAR MECHA ERROR
NOW EXECUTING
COMPLETED
"NOW EXECUTING" is displayed while the data is cleared.
After the data clear is completed, the screen returns to
normal indication after "COMPLETED" is displayed
for 3 seconds.
Data to be Initialized
User setting data of the system micom
(All EEPROM data except the factory default of system
micom, ROM collection data and the Monitor Mecha
Error history.)
The Monitor Mecha Error history is cleared.
Data to be cleared
Monitor Mecha Error history stored in EEPROM.
Monitor Mecha Check mode
MONITOR MECHA CHECK
ANGLE SENSOR MIN : XXXX
ANGLE SENSOR MAX : XXXX
Monitor Mecha Running mode
MONITOR MECHA RUNNING
RUNNING MODE-1
RUNNING MODE-2
RUNNING MODE-3
RUNNING MODE-4
RUNNING MODE-5
RUNNING MODE-6
MENU : BACK
>
DW/UP : SEL MODE : ENT
E-1 : XXXXXX E01 : XXXXXX
E-2 : XXXXXX E02 : XXXXXX
E-3 : XXXXXX E03 : XXXXXX
E-4 : XXXXXX
E-5 : XXXXXX
MENU : BACK
TOTAL ERROR : XXXXXX
This mode is not used for service.
To exit running mode, press the [POWER] button for
more than 3 seconds.
Then service mode is finished.
MIN : Value of the monitor angle 0 C entered by the
initialization processing.
MAX : Value of the monitor angle 105 C entered by the
initialization processing.
(The displayed value is the AD value, which is taken into
the system micom.)
"INITIALIZE OK/NG" indicates completion/incompletion
end of the initialization processing.
("NG" is displayed when mechanism initialization have
not been completed.)
INITIALIZE OK
Read Mecha Error history
READ MECHA ERROR
Total number of errors, the first five and the latest three
errors are displayed.
Clear Mecha Error history
Press the [MENU] button and the screen returns to service mode menu.
Press the [MENU] button and the screen returns to service mode menu.