(No.MA248)1-25
SECTION 4
ADJUSTMENT
4.1
Test instruments required for adjustment
(1) Digital oscilloscope (100MHz)
(2) Jitter meter
(3) Digital tester
(4) Electric voltmeter
(5) Tracking offset meter
(6) Test Disc : VT501 or VT502
(7) Extension studs : STDV001-3P
(8) Extension cable : EXTDV002-30P
4.2
Standard measuring conditions
Caution:
Be sure to attach the heat sink and rear bracket onto the power
amplifier IC and regulator IC respectively, before supply the
power. If voltage is applied without attaching these parts, the
power amplifier IC and regulator IC will be destroyed by heat.
4.3
Connection method
Connection procedure
(1) Attach the front chassis assembly to the main board.
(2) Connect the front panel assembly to the main board.
(3) Attach the heat sink and rear bracket to the main board.
(4) Attach the extension studs to the DVD mechanism assembly.
(5) Connect the DVD mechanism assembly and the main board with a extension cable.
Power supply voltage
DC14.4V(11 to 16V)
Load impedance
4
Ω
(2 Speakers connection)
Line Output
20K
Ω
Main board
Extension cable
EXTDV002-30P
Extension studs
STDV001-3P
Extension stud
STDV001-3P
Heat sink
Rear bracket
Содержание KD-DV4200J
Страница 19: ... No MA248 1 19 Fig 8 Fig 9 Clamper unit Clamper spring Notch g Clamper unit ...