4.6
Service Mode
• Operating key: [MENU]
→
[DOWN] (3 sec)
• Navigation key : Press [SEL] in any main display item to select that option.
• Volume knob turn : forward and backward selection.
INIT ALL
Initialize all data to factory shipment state.
MECHA DISP
CD mechanism No.
RUNNING 1
For use in running tests. (Only factory use)
RUNNING 2
For use in running tests. (Only factory use)
CD ERROR
Display the CD Error past record stored in EEPROM.
Total Error
Latest 3 errors recorded
The first 5 errors recorded
CLR ERR
Clear CD Error history from EEPROM.
CDSERV MODE