(No.YA010)1-37
SUB TINT(1)
Signal
generator
Remote
control unit
[2. V/C]
10. TINT
[Method of adjustment without measuring instruments]
NTSC 3.58 TINT
(1) Input NTSC3.58MHz full field colour bar signal (75%
white).
(2) Select 2. V/C.
(3) Set the initial setting value of < 10. TINT >.
(4) If the tint is not the best with the initial set value,
make fine adjustment until you get the best hue.
(5) Press the [MENU] key and memorize the adjustment
value.
SUB TINT(2)
Signal
generator
Oscilloscope
Remote
control unit
TP-47R
TP-E
[CRT SOCKET
PWB]
[2. V/C]
10. TINT
[Method of adjustment using measuring instruments]
NTSC 3.58 TINT
(1) Input NTSC3.58MHz full field colour bar signal (75%
white).
(2) Select 2. V/C.
(3) Set the initial setting value of < 10. TINT >.
(4) Connect the oscilloscope between TP-47R and
TP-E at the CRT SOCKET PWB.
(5) Adjust < 10. TINT > and bring the value of (B) in the
illustration to the values as shown in the table
(Voltage difference between white (W) and yellow
(Y)).
(6) Press the [MENU] key and memorize the adjustment
value.
Item
Measuring
instrument
Test point
Adjustment part
Description
Initial setting value
Setting item
10.TINT
63
(+)
(-)
0
(75%)
W
Y
Mg
B
R
G
Cy
(B)
Adjustment value
+1V
Setting item
10.TINT