AV-28X37SUE AV-28X37HKE
AV-28X35HKE AV-28X37HIE
AV-28H35SUE AV-28H35BUE
AV-28X35HUE
1-24 (No.52106)
SUB HUE l
adjustment
Remote
control unit
[2.V/C]
11.HUE
[Method of adjustment without measuring instrument]
NTSC 3.58 HUE:
(1) Input a NTSC 3.58MHz COMPOSITE VIDEO signal
(full field colour bar with 75% white) from the EXT
terminal.
(2) Select 2.V/C.
(3) Select 11. HUE.
(4) Set the initial setting value of NTSC 3.58 HUE.
(5) If you cannot get the best hue with the initial setting
value, make fine adjustment until you get the best
hue.
(6) Press the [MENU] key and memorize the set value.
NTSC 4.43 HUE:
(1) When NTSC 3.58 is set, NTSC 4.43 will be
automatically set at the respective values.
SUB HUE ll
adjustment
Signal
generator
Oscilloscope
Remote
control unit
TP-47B
TP-E( )
[CRT
SOCKET
PWB]
[2.V/C]
11.HUE
[Method of adjustment using measuring instrument]
NTSC 3.58 HUE:
(1) Input a NTSC 3.58MHz COMPOSITE VIDEO signal
(full field colour bar with 75% white) from the EXT
terminal.
(2) Select 2.V/C.
(3) Select 11. HUE.
(4) Set the initial setting value of NTSC 3.58 HUE.
(5) Connect the oscilloscope between TP-47B and TP-
E( )
(6) Adjust NTSC 3.58 HUE to bring the value of (B) in
the illustration to the values as shown given billow
(voltage difference between white (W) and magenta
(Mg)).
(7) Press the [MENU] key and memorize the setting
value.
NTSC 4.43 HUE:
(1) When NTSC 3.58 COLOUR set, NTSC 4.43
COLOUR will automatically set.
Item
Measuring
instrument
Test point
Adjustment part
Description
W
M
0V
(-)
(+)
(B)
Y
C
G
R
B
AV-28X37SUE
AV-28X37HIE
AV-28X37HKE
AV-28X35HUE
AV-28X35HKE
AV-28H35SUE
AV-28H35BUE
VOLTAGE (W-M)
-10V
-10V
[VOLTAGE SETTING]