(No.YA063)1-33
SUB HUE-1
Remote
control unit
[2.V/C]
11.HUE
[Method of adjustment without measuring instrument]
NTSC 3.58
(1) Input the NTSC 3.58MHz signal from the EXT
terminal.
(2) Set the ZOOM mode to FULL.
(3) Set the PICTURE MODE to STD.
(4) Select 2.V/C from the SERVICE MENU.
(5) Select < 11. HUE >.
(6) Set the initial setting value of < 11. HUE >.
(7) If you cannot get the best hue with the initial
setting value, make fine adjustment until you get
the best hue.
(8) Press the [MENU] key and memorize the set
value.
NTSC 4.43
(1) When NTSC 3.58 is set, NTSC 4.43 will be
automatically set at the respective values.
SUB HUE-2
Signal
generator
Oscilloscope
Remote
control unit
TP-47B
TP-E
[CRT SOCKET
PWB]
[2.V/C]
11.HUE
[Method of adjustment using measuring instrument]
NTSC 3.58 HUE
(1) Input the NTSC 3.58MHz signal (full field colour
bar with 75% white) from the EXT terminal.
(2) Set the ZOOM mode to FULL.
(3) Set the PICTURE MODE to STD.
(4) Select 2.V/C from the SERVICE MENU.
(5) Select < 11. HUE >.
(6) Set the initial setting value of < 11. HUE >.
(7) Connect the oscilloscope between TP-47B and
TP-E.
(8) Adjust < 11. HUE > to bring the value of (B) in the
illustration to the values as shown given billow
(voltage difference between white (W) and
magenta (M)).
(9) Press the [MENU] key and memorize the set
value.
NTSC 4.43 HUE
(1) When NTSC 3.58 COLOUR set, NTSC 4.43
COLOUR will automatically set.
Item
Measuring
instrument
Test point
Adjustment part
Description
W
M
0V
(-)
(+)
(B)
Y
C
G
R
B
VOLTAGE (W-M)
-10V
[VOLTAGE SETTING]
Voltage setting