(No.YA063)1-27
H. POSITION
Signal
generator
Remote
control unit
[4.DEF]
3.H-CENT
(1) Receive the circle pattern signal.
(2) Set the ZOOM mode to FULL.
(3) Select 4.DEF from the SERVICE MENU.
(4) Select < 3.H-CENT >.
(5) Set the initial setting value of < 3.H-CENT >.
(6) Adjust horizontal position to make C=D.
(7) Press the [MENU] key and memorize the set value.
H.SIZE
Signal
generator
Remote
control unit
[4.DEF]
4.H-SIZE
(1) Receive the circle pattern signal.
(2) Set the ZOOM mode to FULL.
(3) Select 4.DEF from the SERVICE MENU.
(4) Select < 4.H-SIZE >.
(5) Set the initial setting value of < 4.H-SIZE >.
(6) Adjust to make sure that the horizontal screen size
of the picture size is in the bellow table.
(7) Make sure that the horizontal screen size of the each
ZOOM mode is in the below table.
(8) Press the [MENU] key and memorize the set value.
SIDE-PIN
Signal
generator
Remote
control unit
[4.DEF]
6.EW-PIN
(1) Receive the cross-hatch signal.
(2) Set the ZOOM mode to FULL.
(3) Select 4.DEF from the SERVICE MENU.
(4) Select < 6.EW-PIN >.
(5) Set the initial setting value of < 6.EW-PIN >.
(6) Adjust to make the 2nd vertical lines at the left and
right edges of the screen straight. Also make sure
that the 3rd vertical lines are straight.
(7) Press the [MENU] key and memorize the set value.
Item
Measuring
instrument
Test point
Adjustment part
Description
C
D
ZOOM MODE
FULL
PANORAMIC
SUBTITLE
H SIZE
92%
[SCREEN SIZE]
95%
92%
Straight