1-14 (No.YF180)
3.2.4 DISASSEMBLY OF [18] MONITOR ASSY
z
CAUTIONS
(1) During the procedure, be careful in handling the LCD
MODULE and other parts. Pay special attention not to
damage or stain the monitor screen.
If fingerprints are left on the screen, wipe them with clean
chamois leather or a cleaning cloth.
z
Removing MONITOR ASSY
(1) Remove the two screws (1 and 2).
(2) Turn the HINGE UNIT ASSY 90
°
, and remove the two
screws (3 and 4).
(3) Remove the MONI.COVER ASSY by removing the four
hooks (L18a-d).
NOTE18a:
During the procedure, be careful with the handling of
the BUTTON (MONI) located under the MONI BOARD
ASSY.
As the BUTTON (MONI) is held under the COVER, it
may be uplifted or misaligned when the COVER is re-
moved.
(4) Release the lock of the connector (CN18a), and remove
the HINGE UNIT by lifting it up.
NOTE18b:
During the procedure, be careful in handling the FPC.
(5) Release the lock of the connector (CN18b), and pull out
the FPC.
(6) Remove the two screws (5 and 6), and remove the MON-
ITOR BOARD ASSY .
NOTE18c:
During the procedure, be careful with the handling of
the BUTTON (MONI) underneath.
As the BUTTON (MONI) is held under the COVER, it
may be uplifted or misaligned when the COVER is re-
moved.
NOTE18d:
When attaching the MONITOR BOARD ASSY, be
careful to avoid any misalignment or unevenness of
the parts underneath.
Attach the MONITOR BOARD ASSY by lifting up the
MONITOR CASE as the KNOB (CURSOR) that is at-
tached to the BOARD sticks out toward the LCD
screen.
(7) Remove the SHEET (M.REF), LIGHT GUIDE, SHEET
(M/DIFF), SHEET(BEF)2, and the SHEET(BEF)1.
NOTE18e:
When attaching, insert one side of the SHEET (M/
DIFF) under the LCD CASE RIB.
NOTE18f:
When attaching, insert each tab on both sides of the
SHEET (M.REF) into the LCD CASE notch.
(8) Remove the LCD CASE, SPACER(LCD-2), LCD MOD-
ULE, SPACER(LCD) and the LCD BKT ASSY.
NOTE18g:
During the procedure, handle the five parts (LCD CASE,
SPACER(LCD-2), LCD MODULE, SPACER(LCD) and
the LCD BKT ASSY) together.
z
Removing HINGE UNIT ASSY
(1) Remove the screw (7), and Remove the HINGE COV-
ER(U).
(2) Remove the HINGE COVER(L).
(3) Remove the MAGNET.
NOTE18h:
During the procedure, be careful in handling the mag-
net.
When attaching, set the N pole outside as shown in
the figure. Be careful when removing as there is no
marking.
NOTE18j:
During the procedure, be careful in handling the FPC.
NOTE18k:
The FPC, with its connection to the MONITOR BOARD
ASSY facing inward, is rolled around the axis (shaft) of
the HINGE UNIT ASSEY rotation 2.5 rounds
(2.5times).