23
CONTROLS, INDICATORS AND CONNECTORS
5
Audio sampling frequency in-
dication
32 K : Indicated when the AUDIO MODE item on the AUDIO/MIC [1/2] menu screen is set to 32 K. (Au-
dio is recorded with 12-bit, 32 kHz sampling.)
48 K : Indicated when the AUDIO MODE item on the AUDIO/MIC [1/2] menu screen is set to 48 K. (Au-
dio is recorded with 16-bit, 48 kHz sampling.)
X
See page 72.
6
Audio level meter indication
Displays the CH-1, CH-2 audio level meters.
Whether or not to display this item is set with the AUDIO item on the LCD/VF [2/3] menu.
X
See page 75.
7
Standard audio level indication The level at which audio is recorded on the tape is indicated by “
O
”.
–20 dB, –12 dB
X
See “AUDIO REF.LEVEL” on page 72.
8
Iris indicator display
M
: Iris set higher than normal
b
: Iris set to normal
N
: Iris set lower than normal
9
Iris F-value indication
Indicates the F-number of the connected lens.
OPEN, F2, F2.8, F4, F5.6, F8, F11, F16, CLOSE
It is not displayed when the lens is removed. For some lenses, no display appears.
The indication can be switched ON/OFF with the F.NO/IRIS IND. item on the LCD/VF [1/3] menu screen.
X
See page 74.
0
Filter position indication
Indicates the current filter position.
No display: FILTER OFF
ND1: FILTER ND1 (1/4ND)
ND2: FILTER ND2 (1/16ND)
The indication can be switched ON/OFF with the FILTER item on the LCD/VF [1/3] menu screen.
X
See page 74.
No.
Item
Contents
–20 dB
–12 dB
O
O
CH-1
O O O O O O O O O \ \ \ ]
CH-2
O O O O O O O O O \ \ \ ]
Содержание GY- HD111 HD CAMERA RECORDER
Страница 2: ......
Страница 100: ...GY HD110 GY HD111 HD CAMERA RECORDER LST0392 001B 2006 Victor Company of Japan Limited ...