1-24 (No.86772)
5.3
EMERGENCY DISPLAY
Whenever some abnormal signal is input to the syscon CPU, an
error number (E01, as an example) is displayed on the LCD
monitor or (in the electronic view finder).In every error status,
such the message as shown below alter nately appear over and
over.
• In an emergency mode, all operations except turning on/off the
POWER switch are ineffectual.
Example (in case of the error number E01):
Fig.5-3-1
E01
UNIT IN
SAFEGUARD MODE
E01
REMOVE AND
REATTACH BATTERY
LCD display
Emergencymode
Details
Possible cause
E01
LOADING
In the case the encoder position is
not shifted to the next point though
the loading motor has rotated in the
loading direction for 4 seconds or
more. This error is defined as [E01].
1. The mechanism is locked during mode shift.
2. The mechanism is locked at the mechanism loading end,
because the encoder position is skipped during
mechanism mode shift.
3. No power is supplied to the loading MDA.
E02
UNLOADING
In the case the encoder position is
not shifted to the next point though
the loading motor has rotated in the
unloading direction for 4 seconds or
more. This error is defined as [E02].
1. The mechanism is locked during mode shift.
2. The mechanism is locked at the mechanism loading end,
because the encoder position is skipped during
mechanism mode shift.
E03
TU & SUP REEL FG In the case no REEL FG is
produced for 4 seconds or more in
the capstan rotation mode after
loading was complete, the
mechanism mode is shifted to
STOP with the pinch roller set off.
This error is defined as
[E03].However, no REEL EMG is
detected in the SLW/STILL mode.
1. The idler gear does not engage with the reel disk well.
2. Though the idler gear and reel disk are engaged with
each other, the tape is not wound because of overload
to the mechanism.
3. No FG pulse is output from the reel sensor.
4. No power is supplied to the reel sensor.
5. Tape transport operation takes place with a cassette
having no tape inside.
6. The tape slackens and no pulse is produced until the
slack is taken up and the tape comes into the normal
status.
E04
DRUM FG
In the case there is no DRUM FG
input in the drum rotation mode for
4 seconds or more. This error is
defined as [E04], and the
mechanism mode is shifted to
STOP with the pinch roller set off.
1. The drum cannot be started or drum rotation is stopped
because tape transport load is too high.
1) Tape tension is extremely high.
2) The tape is damaged or soiled with grease, etc.
2. The DRUM FG signal is not received by the syscon CPU.
1) Disconnection in the middle of the signal line.
2) Failure of the DRUM FG pulse generator (hall
element).
3. No drum control voltage is supplied to the MDA.
4. No power is supplied to the DRUM MDA.
E05
-
-
-
E06
CAPSTAN FG
In the case no CAPSTAN FG is
produced in the capstan rotation
mode for 2 seconds or more. This
error is defined as [E06], and the
mechanism mode is shifted to
STOP with the pinch roller set
off.However, no CAPSTAN EMG is
detected in the STILL/FF/REW
mode.
1. The CAPSTAN FG signal is not received by the syscon
CPU.
1) Disconnection in the middle of the signal line.
2) Failure of the CAPSTAN FG pulse generator (MR
element).
2. No capstan control voltage is supplied to the MDA.
3. The capstan cannot be started or capstan rotation is
stopped because tape transport load is too high.
1) Tape tension is extremely high. (Mechanical locking)
2) The tape is damaged or soiled with grease, etc. (Tape
tangling occurs, etc.)