No. 51957
GM-P421U
GM-P420UG
42
Item
Test equipment
Test points
Ad justment
locations
Ad justment procedure
*
VGA signal 640
×
480 dots (Ramp pattern)
Horizontal Frequency : 31.5kHz
Vertic al frequency : 60Hz
RGB offset
(VGA)
adjustment
Oscilloscope
PC Video
signal
generator
CH01
WA04
(R cut off)
WA06
(B cut off)
1. Input the VGA signal ramp pattern to the PC-IN terminal.
2. Change the value in the
<
SERVICE MENU
>
CH01 from “0”
to “2” to enter the tes t mode for RGB balance.
3. Adjust the values in the
<
SERVICE MENU
>
WA04 (R cut
off) and WA06 (B c ut off) so that the 3 lines on the left part of
the PDP s creen are aligned. Keep the WA05 (G cut off) intact.
4. Return the value in the
<
SERVICE MENU
>
CH01 from “2” to
“0”.
*
RGB 15k VIDEO signal (Ramp pattern)
Horizontal Frequency : 15.75kHz
Vertic al frequency : 59.94Hz
RGB offset
(RGB 15k)
adjustment
Oscilloscope
PC Video
signal
generator
CH01
WI04
(R cut off)
WI06
(B cut off)
1. Input the RGB15k video signal ramp pattern to the PC-IN
terminal.
2. Change the value in the
<
SERVICE MENU
>
CH01 from “0”
to “2” to enter the tes t mode for RGB balance.
3. Adjust the values in the
<
SERVICE MENU
>
WI04 (R c ut off)
and WI06 (B cut off) s o that the 3 lines on the left part of the
PDP s creen are aligned. Keep the WI05 (G cut off) intact.
4. Return the value in the
<
SERVICE MENU
>
CH01 from “2” to
“0”.
(RAMP pattern)
Align the 3 lines on the left part.
(RAMP pattern)
Align the 3 lines on the left part.