INITIALIZATION OF SELF-DIAGNOSIS
<
<
<
<
FOR CHECKING THE DIAGNOSIS HISTORY
>
>
>
>
1. Enter the SERVICE MENU as shown Fig. 1.
2. Display the sec ond page by pressing the SELECT :
▲
key or
▼
key (Fig. 2) .
3. After moving the cursor to DIAGNOSIS, display DIAGNOSIS
BLOCK (Fig. 3) by pressing the ENTER : key.
4. Confirm that every item is indicated by a
○
○
○
○
mark.
5. If any item is indic ated by a
×
×
×
×
mark, press the key to display
as s hown in Fig. 4.
6. When the ENTER : key is pressed again, eac h item will be
indic ated by a
○
○
○
○
mark (Fig. 5) .
7. Self-diagnosis will be initialized.
<
<
<
<
SELF CHECK BY LED
>
>
>
>
"
This plasma display monitor is equipped with a self-diagnosis function by the LED indication.
"
If an abnormality is detected, the three LED indicators on the upper left of the PDP will turn on or flash.
SELF-DIAGNOSIS ITEMS & LED LIGHTING / FLASHING
LED
Detected items
upper
center
lower
Priority
E2PROM communication
error
○
○
☆
6
Panel alarm
☆
☆
○
5
High temp. ( Power )
☆
○
○
4
High temp.(Temp. sensor) A
☆
○
☆
3
High temp.(Temp. sensor) B
☆
☆
○
2
Flash write abnormality
☆
☆
☆
1
Note:
・
displayed color: RED
・
flashing interval: 0.25s ON, 0.25s OFF
・
LEDs indicate just 1 detected item that has priority even