4 Command control
60 / 61
PJ04030102B
5
Additional Information for isf Adjustment
5.1
State Transition Diagram
Fig.5-1 State transition chart
・
<>: Remote Control code
・
【】
: RS232C Command
・
When power goes off during “Adjust(During Adjustment)”, State moves to “ON(After Adjustment)” automatically.
・
No Link with THX Adjustment.(THX Adjustment is possible regardless of isf Adjustment mode.)
5.2
Remote Control code
Remote control code relating to isf adjustment is as follows.
Table 5-1
Remote control code relating to isf
No Remote control code
Meaning
Comments
1
0x05
Power On
Power on when PJ is in stand-by state.
2
0x06
Power Off
Power off when PJ is in power-on state.
3
0x58
isf Adjust State
Move to isf Adjustment state.
4
0x5A
isf Off
Move to isf Off state (Factory default)
5
0x5B
isf On
Move to isf After Adjustment state
[1] isf :Off (Before adjustment: Factory default)
・
isf selection: Not possible
・
Adjustment: Not possible
Power off state(Stand-by)
[2] isf :Adjust (During Adjustment)
・
isf selection: Possible
・
Adjustment: Possible
[3] isf :ON(After Adjustment)
・
isf selection: Possible
・
Adjustment: Not possible
<0x05>
【
PW:1
】
Power on state
<0x06>
【
PW:0
】
<0x58>
【
PMIE:2
】
<0x5B>
【
PMIE:1
】
<0x5A>
【
PMIE:0
】
<0x5A>
【
PMIE:0
】
<0x5B>
【
PMIE:1
】
<0x58>
【
PMIE:2
】