4.8
Gamma coefficient of Gamma table ”Custom1/2/3” [GammaPower]
Used to switch the gamma coefficient when the gamma table is Custom 1/2/3 and to refer the gamma coefficient.
Target of switching and referencing is followed by setting value of the Gamma bank.
Command code
Table 4-15 GAMMA POWER CMD
HEX
ASCII
Function
Operation Reference
0x47
0x50
'G'
'P'
Gamma coefficient of Gamma table ”Custom 1/2/3”
[GammaPower]
Parameters
Data length: 1
【
Data 0
】
Table 4-16 GAMMA POWER CMD DATA
HEX
ASCII
Operation
0x30
‘0’
1.8
0x31
‘1’
1.9
0x32
‘2’
2.0
0x33
‘3’
2.1
0x34
‘4’
2.2
0x35
‘5’
2.3
0x36
‘6’
2.4
0x37
‘7’
2.5
0x38
‘8’
2.6
When the projector is not powered on and it receives the command, the projector ignores the command and does not respond.