No.51866
AV-T2122
18
■
■
■
■
ADJUSTMENTS
!!!!
B1 POWER SUPPLY
Item
Measuring
instrument
Test point
Adjustment item
Description
Check of
B1 POWER
SUPPLY
DC Voltmeter B1 (
B1
Connector
1
pin)
(TP-91)
TP-E(
#
)
(
B1
Connector
3
pin)
1. Receive a black and white signal (color off). (NTSC)
2. Connect the DC voltmeter to B1 connector 1 pin (TP-91)
and TP-E(
#
) (B1 connector 3 pin).
3. Confirm that the voltage is DC134.5V
±
2V.
IF VCO ADJUSTMENT
Item
Measuring
instrument
Test point
Adjustment item
Description
IF VCO
adjustment
Signal
generator
CW TRANSF. (T111)
[VCO (CW)] mode
"
Under normal conditions, no adjustment is required.
1. Receive a broadcast. (use channels without offset frequency).
2. Select the VCO(CW) mode from the SERVICE MENU.
3. Confirm the color change (yellow) from
“
TOO HIGH
”
to
“
TOO LOW
”
by CW TRANSF. and
“
SYNC : YES
”
being
shown on the screen. Then, adjust CW TRANSF. until
“
BELOW REFERENCE
”
mark turns yellow and confirm
again
“
SYNC : YES
”
being shown on the screen.
RF AGC ADJUSTMENT
RF AGC
adjustment
No.60 RF AGC
1. Receive a broadcast.
2. Select “No.60 RF AGC” of the PICTURE mode in SERVICE
MENU.
3. Press the MUTE key and turn off color.
4. With the MENU LEFT key, get noise in the screen picture. (0
side of setting value)
5. Press the MENU RIGHT key and stop when noise disappears
from the screen.
6. Change to other channels and make sure that there is no
irregularity.
7. Press the MUTE key and get color out.
FOCUS ADJUSTMENT
FOCUS
adjustment
Signal
generator
FOCUS VR
[In HVT]
1. Receive a crosshatch signal.
2. While looking at the screen, adjust FOCUS VR so that the
vertical and horizontal lines will be clear and in fine detail.
3. Make sure that the picture is in focus even when the screen
gets darkened.
EXIT BY
IT
TOO HIGH
ABOVE REFERENCE
BELOW REFERENCE
TOO LOW
SYNC : YES
EXIT
YELLOW