19
ENGLISH
Controlling this unit externally
The control panel and the ON-SCREEN ADJUSTMENTS functions can be controlled via an external device such as a personal
computer.
Information on communication protocols and commands is available separately. For details, consult your JVC dealer.
Connection with a personal computer
1.
Turn this unit and the personal computer off.
2.
Connect the personal computer to the REMOTE IN connector on the rear panel of this unit with an RS-232C cable.
3.
Turn this unit and the personal computer on.
4.
Set the computer’s RS-232C communication settings as specified in the interface specifications.
5.
Start up the control program on the computer.
Interface specifications
•
Communication method : Full duplex asynchronous
•
Baud rate
: 9600 bps
•
Start bit
: 1 bit
•
Stop bit
: 1 bit
•
Data length
: 8 bits
•
Parity
: Even parity
RS-232C Cable
Connection to a serial port
(AV-P1000)
(PC)
D-sub 9-pin female
D-Sub 9-pin female
CD
1 ................................................... 1
CD
TXD
2 ................................................... 2
RD
RXD
3 ................................................... 3
TD
DTR
4 ................................................... 4
DTR
SG
5 ................................................... 5
SG
DSR
6 ................................................... 6
DSR
RTS
7 ................................................... 7
RTS
CTS
8 ................................................... 8
CTS
RI
9 ................................................... 9
RI
System connections
5
10
15
1
6
11
Pin No.
1
Signal name
RED
2
GREEN
3
BLUE
4
NC
5
GND
6
GND
7
GND
8
GND
9
NC
10
GND
11
NC
12
NC
13
Hs/Cs
14
Vs
15
NC
(female)
Connector pin assignments and signal name
RGB OUT2 connector
PC IN connector