3.6.8 HOW TO CHECK THE HIGH VOLTAGE HOLD DOWN CIRCUIT
3.6.8.1
HIGH VOLTAGE HOLD DOWN CIRCUIT
After repairing the high voltage hold down circuit.
This circuit shall be checked to operate correctly.
3.6.8.2
CHECKING OF THE HIGH VOLTAGE HOLD DOWN CIRCUIT
(1) Turn the power switch to on.
(2) Refer to the following figure, set the resistor between
X
connector
1
and
3
.
(3) Make sure that the screen picture disappears.
(4) Temporarily unplug the power plug.
(5) Remove the resistor replaced
X
connector
1
and
3
.
(6) Again plug the power plug, make sure that the normal picture is displayed on the screen.
T521
CONNECTOR
RESISTOR
18.00 k
ǡr
1%
HEATER
X
3
2
1
POWER
ON OFF
4