No. 51833
AV-N29220
17
Item
Measuring
instruments
Test point
Adjustment part
Description
V.SIZE
Adjustment
Signal
generator
No.13 V.SIZE
1. Receive a crosshatch signal.
2. Select No.13 V.SIZE in the PICTURE MODE.
3.
Set the initial setting value of No.13 V.SIZE with the LEFT /
RIGHT key of the MENU.
4. Adjust No.13 V.SIZE until the vertical screen size is 92%.
H.POSITION
Adjustment
Signal
generator
No.15 H.POS
1. Receive a crosshatch signal.
2. Select the No.15 H.POS of the PICTURE MODE.
3. Set the initial setting value of the No.15 H.POS with the LEFT /
RIGHT key of the MENU.
4.
Adjust the No.15 H.POS until the screen will be horizontally
centered.
Screen size
Picture size 100%
Screen
size
92%
Picture
size
100%