No. 52007
AV-56WP30
38
Item
Measuring
instrument
Test point
Ad justment part
Description
SIDE PIN
adjustment
D02: EW PARABOLA
D08: EW CORNER
LOWER
D09: EW CORNER
UPPER
16. Select D02<EW PARABOLA>, D08<EW CORNER LOWER>,
D09
<
EW CORNER UPPER
>
with FUNCTION (
▲
/
▼
) key
respectively.
17. Adjust D02, D08, D09 with FUNCTION ( / ) key and make
the vertic al lines at the left and right edges of the screen
straight.
18. Press the MUTING key and memorize the set value.
NOTE
:
After making adjustments, confirm that the horizontal position is
properly adjusted. If the horizontal is out of alignment, readjust it.
Adjust H SIZE & SIDE PIN reparably .
TRAPEZIUM
adjustment
D07: TRAPEZ IUM
19. Select D07
<
TRAPEZIUM
>
with the FUNCTION (
▲
/
▼
) key.
20. Adjust D07 with ( / )key and bring the vertical lines at the
right and left edges of the screen parallel.
21. Press the MUTING key and memorize the set value.
Parallel
Straight