AV-34LS
AV-34LX
AV-34LH
AV-3408TEE
No. 51854
29
Item
Measuring
instrument
Test point
Adjustment part
Description
Adjustment
of
VER. SCURVE
4. VER. SCURVE
29. Select
4. VER. SCURVE
with the MENU
&
/
^
key.
30.Set the initial setting value of
4. VER. SCURVE
with the MENU –/+
key.
31. Adjust
4. VER. SCURVE
so that the spaces of each line on TOP,
CENTRE and BOTTOM become uniform.
TOP
CENTRE
BOTTOM
Adjustment
of
UP CORNER
and
DW CORNER
9. UP CORNER
10. DW CORNER
32. Select
9. UP CORNER
with the MENU
&
/
^
key.
33. Set the initial setting value of
9. UP CORNER
with the MENU –/+
key.
34. Sekect
10. DW CORNER
with the MENU
&
/
^
key.
35. Set the initial setting value of
10. DW CORNER
with the MENU –/+
key.
36. Adjust
9. UP CORNER
and
10. DW CORNER
so that the vertical
lines at the four corners on the screen are straight.
Signal
generator
Remote
control unit
Adjustment
of
HOR. PARALL
11. HOR. PARALL
37. Select
11. HOR. PARALL
with the MENU
&
/
^
key.
38. Set the initial setting value of
11. HOR. PARALL
with the MENU
–/+ key.
39. Adjust
11. HOR. PARALL
to optimize the parallelogram distortion.
Signal
generator
Remote
control unit
Adjustment
of
HOR. BOW
12. HOR. BOW
40. Select
12. HOR. BOW
with the MENU
&
/
^
key.
41. Set the initial setting value of Select
12. HOR. BOW
with the MENU
–/+ key.
42. Adjust
12. HOR. BOW
to optimize the horizontal arc distortion.
43. Press the DISPLAY key twice to return to the normal screen.
Signal
generator
Remote
control unit
Straight
Signal
generator
Remote
control unit
Adjustment
of
EW-TRAPEZ
8. EW-TRAPEZ
26. Select
8. EW-TRAPEZ
with the MENU
&
/
^
key.
27. Set the initial setting value of
8. EW-TRAPEZ
with the MENU –/+
key.
28. Adjust
8. EW-TRAPEZ
so that the vertical lines at the left and right
edges on the screen are in parallel.
Parallel
Signal
generator
Remote
control unit