(No. 52195) 1-29
Item
Measuring
instrument
Test point
Adjustment part
Description
4.6.6 VSM PRESET SETTING
Item
Measuring
instrument
Test point
Adjustment part
Description
H. POSITION
adjustment
[3. DEF]
5. HOR. POSITION
(1) Input a PAL circle pattern signal to VIDEO-2 terminal.
(2) Select VIDEO-2 SET from the MENU and set VIDEO-2
SET to COMPONENT.
(3) Select
3. DEF
from the SERVICE MENU.
(4) Select
5. HOR. POSITION
.
(5) Set the initial setting value of
5. HOR. POSITION
.
(6) Adjust
5. HOR POSITION
to make “
C=D
”.
(7) Press the [DISPLAY] key twice to return to the normal
screen.
Signal
generator
Remote
control unit
!
VIDEO - 2 SET : COMPONENT, fv: 50/60Hz mode
VSM
PRESET
setting
[4. VSM PRESET]
1. TINT
2. COLOR
3. BRIGHT
4. PICTURE
5. DETAIL
Remote
control unit
(1) Select
4. VSM PRESET
from the SERVICE MENU.
(2) Select BRIGHT with the [PICTURE MODE] key.
(3) Adjust to reset the set values of
1. TINT
~
5. DETAIL
to the
values shown in the table.
(4) Respectively select the VSM PRESET mode for SOFT and
STANDARD, and make similar adjustment as in 3 above.
(5) Press the [DISPLAY] key twice to return to the normal
screen.
SUB MENU 4. VSM PRESET
TINT
**
COLOR
**
BRIGHT
**
PICTURE
**
DETAIL
**
BRIGHT
MENU
: SELECT
MENU - / + : OPERATE
DISPLAY : EXIT
C
D
VSM preset
VSM
mode
BRIGHT
STANDARD
SOFT
setting item
TINT
15
←
←
COLOR
15
←
←
BRIGHT
15
←
←
PICTURE
30
15
11
DETAIL
15
←
7
[Setting Values for SUB 4. VSM PRESET]