No. 52085
AV-29BH11ENS
AV-29BH11EPS
AV-29BH11EES
16
Item
Measuring
instrument
Test point
Adjustment part
Description
SIDE PIN
adjustment
Signal
generator
Remote
control unit
PARAB
1.
Receive a cross-hatch signal.
2.
Enter the SERVICE MENU.
3. Press the RED key on the remote control unit, then enter
the H/V adjustment group.
4.
Select PARAB with the UP/DOWN ( / ) key.
5. Adjust PARAB with the LEFT/RIGHT ( / ) key till vertical
lines close to the both sides of the picture frame become
parallel to vertical sides of picture tube without any bending
to left or to right side of the screen.
6. Check and readjust PARAB item if the adjustment becomes
improper after some other geometric adjustments are done.
7.
Press the INFORMATION key and memorize the set value.
CORNER
adjustment
Signal
generator
Remote
control unit
U.COR
L.COR
1.
Receive a cross-hatch signal.
2.
Enter the SERVICE MENU.
3. Press the RED key on the remote control unit, then enter
the H/V adjustment group.
4.
Select U.COR with the UP/DOWN ( / ) key.
5. Adjust U.COR with the LEFT/RIGHT ( / ) key till vertical
lines at the upper corners of the picture frame become
vertical and parallel to vertical corner sides of picture tube.
6. Check and readjust U.COR item if the adjustment becomes
improper after some other geometric adjustments are done.
7.
Press the INFORMATION key and memorize the set value.
8.
Select L.COR with the UP/DOWN ( / ) key.
9. Adjust L.COR with the LEFT/RIGHT ( / ) key till vertical
lines at the lower corners of the picture frame become
vertical and parallel to vertical corner sides of picture tube.
10. Check and readjust L.COR item if the adjustment becomes
improper after some other geometric adjustments are done.
11. Press the INFORMATION key and memorize the set value.
Parallel
Straight
Straight