No. 52085
AV-29BH11ENS
AV-29BH11EPS
AV-29BH11EES
10
BASIC OPERATION SERVICE MENU
■
■
■
■
HOW TO ENTER THE SERVICE MODE
1) Press
the
INFORMATION
key and
MUTING
key of
REMOTE CONTROL UNIT simultaneously, and the
SERVICE MENU screen of Fig.1 will be displayed.
2) While the Fig.1 is displayed, press the
BLUE
key for
access to the SERVICE MENU (2/2) (Fig.2).
■
HOW TO EXIT SERVICE MODE
1)
Press the
MENU
Key on REMOTE CONTROL UNIT.
REMOTE CONTROL UNIT key NAME
MUTING key
UP / DOWN
( / ) key
INFORMATION
key
COLOUR key
LEFT / RIGHT
( / ) key
BLUE key
YELLOW key
RED key
GREEN key
AK41 G035
18. 12. 2001
SERVICE
H/V
V-SHIFT
000
V-SIZE
0038
H-SHIFT
1224
H-SIZE
023
S-COR
027
LINRT
-07
ANGLE
003
BOW
002
TRAPEZ
-07
PARAB
-39
U.COR
-01
L.COR
002
TILT
000
TRPZD
018
VIDEO
WdR
079
WdG
064
WdB
067
CuR
064
CuG
064
CuB
064
YDP
-04
AGC
045
APSW
2
APS
ON
T_T
THO
T_P
SAM
YDS
-06
YDN
-01
DVD
OFF
C.M
OFF
BLUE
ON
SERVICE MENU (1/2)
Fig.1
PRODUCTION i >STORE MENU >EXIT
OPTIONS
0.HPHONE OFF
1.CRT
4:3
2.S-VHS
OFF
3.f(IF)
38.9
4.Turk
ON
5.VGA
OFF
6.FRONT
ON
7.DPL
OFF
8.VD
OFF
9.NSL
ON
SERVICE MENU (2/2)
ADJUSTMENTS
PIP CNTRST
000
PIP YDelay
000
PIP Frame
0
EHTHP
001
EHTH TC
000
EHTH
-36
EHTV
-14
EHTV TC
005
SVDEL
000
BCLTHRES
T1
OSD CONT
080
OSD BRI
035
TEXT BRI
030
INIT NVM
Prescaler
FM
015
NICAM
035
I2S
016
SCART
025
SYSTEM
0.PAL
B/G
ON
1.PAL
D/K
OFF
2.PAL
I
OFF
3.SECAM
B/G ON
4.SECAM
D/K OFF
5.SECAM
L/L’ ON
6.AUST.
OFF
Fig.2
PRODUCTION i >STORE MENU >EXIT
MENU key