(No.YA060)1-33
4.8.5 VSM PRESET SETTING
4.8.6 AUDIO CIRCUIT
• Do not adjust 3.AUDIO of the SERVICE MENU. Not to change the values of 1. DCX0 ADJ., 2. ERROR LIMIT. 3. A2 ID THR .
Item
Measuring
instrument
Test point
Adjustment part
Description
VSM PRESET
Remote
control unit
[5.VSM PRESET]
(BRIGHT/STD/SOFT)
1. BRIGHT
2. CONT.
3. COLOUR
4. SHARP
5. HUE
(COOL/WARM/NORMAL)
1. WDR R
2. WDR G
3. WDR B
(1) Set the ZOOM mode to FULL.
(2) Select 5.VSM PRESET from the SERVICE MENU.
(3) Press the [MENU] key, and set the PICTURE MODE
to BRIGHT.
(4) Adjust the [FUNCTION UP/DOWN] and [-/+] key to
bring the set values of 1.BRIGHT to 5. HUE to the
values shown in the [5. VSM PRESET].
(5) Press the [MENU] key, and set the PICTURE MODE
to STD.
(6) Make similar adjustment as in 3 above.
(7) Press the [MENU] key, and set the PICTURE MODE
to SOFT.
(8) Make similar adjustment as in 3 above.
(9) Press the [MENU] key, and set the COLOUR TEMP
to COOL.
(10) Adjust the [FUNCTION UP/DOWN] and [-/+] key to
bring the set values of 1.WDR R to 3. WDR B to the
values shown in the table.
(11) Press the [MENU] key, and set the COLOUR TEMP
to WARM.
(12) Make similar adjustment as in 9 above.
(13) Press the [MENU] key, and set the COLOUR TEMP
to NORMAL.