1-32 (No.YA060)
SUB HUE-2
Signal
generator
Oscilloscope
Remote
control unit
TP-47B
TP-E
[CRT SOCKET
PWB]
[2.V/C]
7.HUE
[Method of adjustment using measuring instrument]
NTSC 3.58 HUE
(1) Input the NTSC 3.58MHz signal (full field colour
bar with 75% white) from the EXT terminal.
(2) Set the ZOOM mode to FULL.
(3) Set the PICTURE mode to STD.
(4) Select 2.V/C from the SERVICE MENU.
(5) Select < 7. HUE >.
(6) Set the initial setting value of < 7. HUE >.
(7) Connect the oscilloscope between TP-47B and
TP-E.
(8) Adjust < 7. HUE > to bring the value of (B) in the
illustration to the values as shown given billow
(voltage difference between white (W) and
magenta (M)).
(9) Press the [MENU] key and memorize the setting
value.
NTSC 4.43 HUE
(1) When NTSC 3.58 COLOUR set, NTSC 4.43
COLOUR will automatically set.
SECAM
BLACK OFFSET
Signal
generator
Remote
control unit
TP-47B
TP-E
[CRT SOCKET
PWB]
[2.V/C]
8. BLACK OFFSET
(1) Receive the SECAM full field colour bar signal.
(2) Set the ZOOM mode to FULL.
(3) Set the PICTURE mode to STD.
(4) Select 2. V/C from the SERVICE MENU.
(5) Select < 8. BLACK OFFSET >.
(6) Set the initial setting value of < 8.BLACK OFFSET >.
(7) Connect the oscilloscope between TP-47B and TP-
E at the CRT SOCKET PWB.
(8) Press [1] and [2] keys alternately (turn the colour on
and off), check the waveform of difference in the
voltage.
(9) While looking at the waveform, adjust < 8.BLACK
OFFSET > to become same level of the signal
voltage of black and white waveform by pressing [6]
or [9] keys of remote control unit.
(10) Press the [MENU] key and memorize the set value.
Item
Measuring
instrument
Test point
Adjustment part
Description
W
M
0V
(-)
(+)
(B)
Y
C
G
R
B
VOLTAGE (W-M)
-10V
[VOLTAGE SETTING]
Voltage setting
1
4
7
2
5
8
0
3
6
9
AV
3D
B-Y
B-Y
R-Y
R-Y
B/W mode
COLOUR mode
It adjusts so that the voltage of B/W and
COLOUR waveform may become the same.
Colour waveform
Black and White waveform
[ TP-47B WAVEFORM ]