1-18 (No.YA316)
4.6.5 VIDEO CIRCUIT ADJUSTMENT
Item
Measuring
instrument
Test point
Adjustment part
Description
WHITE
BALANCE
adjustment
Signal
generator
Remote
control unit
WdR
WdG
WdB
(1) Receive a black & white signal.
(2) Enter the SERVICE MODE.
(3) Press the [
GREEN
] key to enter the
VIDEO
adjustment group.
(4) Select
WdR
,
WdG
and
WdB
respectively.
(5) Adjust
WdR
,
WdG
and
WdB
respectively, until the
white part turns to pure white without any other colour.
(6) Press the [
INFORMATION
] key to memorize the set
value.
COLOUR
CUTOFF
LEVEL
adjustment
Remote
control unit
CuR
CuG
CuB
(1) Enter the SERVICE MODE.
(2) Press the [
GREEN
] key to enter the
VIDEO
adjustment group.
(3) Select
CuR
,
CuG
and
CuB
respectively.
(4) Set the values of these items as
128
(constant).
(5) Press the [
INFORMATION
] key to memorize the set
value.
PAL
Y DELAY
adjustment
Signal
generator
Remote
control unit
YDP
(1) Receive a
PAL
colour bar signal.
(2) Enter the SERVICE MODE.
(3) Press the [
GREEN
] key to enter the
VIDEO
adjustment group.
(4) Select
YDP
.
(5) Adjust
YDP
until the colour transients on the colour bar
pattern become as sharper as possible and colours
between transients do not mix with each other.
(6) Press the [
INFORMATION
] key to memorize the set
value.
SECAM
Y DELAY
adjustment
Signal
generator
Remote
control unit
YDS
(1) Receive a
SECAM
colour bar signal.
(2) Enter the SERVICE MODE.
(3) Press the [
GREEN
] key to enter the
VIDEO
adjustment group.
(4) Select
YDS
.
(5) Adjust
YDS
until the colour transients on the colour
bar pattern become as sharper as possible and
colours between transients do not mix with each
other.
(6) Press the [
INFORMATION
] key to memorize the set
value.
NTSC
Y DELAY
adjustment
Signal
generator
Remote
control unit
YDN
(1) Receive a
NTSC
colour bar signal from an external
source (e.g. FRONT AV : EXT 4).
(2) Enter the SERVICE MODE.
(3) Press the [
GREEN
] key to enter the
VIDEO
adjustment group.
(4) Select
YDN
.
(5) Adjust
YDN
until the colour transients on the colour
bar pattern become as sharper as possible and
colours between transients do not mix with each
other.
(6) Press the [
INFORMATION
] key to memorize the set value.