![JVC AV-25MS16 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/jvc/av-25ms16/av-25ms16_service-manual_181805030.webp)
1-30 (No.YA445)
4.8.6 VSM PRESET SETTING
Item
Measuring
instrument
Test point
Adjustment part
Description
VSM PRESET
Remote
control unit
[5.VSM W/B]
1. BRIGHT
2. CONT
3. COLOUR
4. SHARP
5. HUE
1. R-DRIVE
2. G-DRIVE
3. B-DRIVE
(1) Select
5.VSM W/B
from the SERVICE MODE.
(2) Select the
BRIGHT
with the
[OK]
key.
(3) Adjust the
[MENU
/
]
key to bring the set values
of
<1. BRIGHT>
-
<5. HUE>
to the values shown in
the table.
(4) Press the
[OK]
key to memorize the set values.
(5) Respectively select the VSM PRESET mode for
STANDARD
,
SOFT
and
THEATER
.
(6) Select
COOL
with the
[OK]
key.
(7) Adjust the
[MENU
/
]
key to bring the set values
of
<1. R DRIVE>
to
<3. B DRIVE>
to the values
shown in the table.
(8) Press the
[OK]
key to memorize the set values.
(9) Respectively select the WIHITE BALANCE mode for
WARM
and
NORMAL
.
1. R DRIVE
0
2. G DRIVE
0
0
3. B DRIVE
-12
-4
+10
-34
-9
0
0
-10
+2
W/B preset
COOL
NORMAL
WARM
Setting item
THEATER
[AV-25MX16/S, AV-25MX56/S]
Setting item
Variable
range
Setting value
BRIGHT
SOFT
STANDARD
THEATER
1. BRIGHT
-16 - 16
0
0
0
+0
2. CONT.
-16 - 16
+15
+5
+10
+8
3. COLOUR
-16 - 16
0
+0
-4
-7
4. SHARP
-16 - 16
0
-10
-5
+0
5. HUE
-16 - 16
0
0
0
-1
[AV-25MS16/H, AV-25MX16/G]
Setting item
Variable
range
Setting value
BRIGHT
SOFT
STANDARD
THEATER
1. BRIGHT
-16 - 16
0
0
0
+2
2. CONT.
-16 - 16
+15
+5
+10
+3
3. COLOUR
-16 - 16
0
+0
-4
-7
4. SHARP
-16 - 16
0
-10
-5
+0
5. HUE
-16 - 16
0
0
0
-1