1-26 (No.YA445)
VIDEO - 2 SET: COMPONENT
TRAPEZIUM
Signal
generator
Remote
control unit
[4. DEF]
6. TRAPEZ
PAL TRAPEZIUM PIN
(1) Receive a PAL crosshatch signal.
(2) Set the COMPRESS(16 : 9) to ON.
(3) Select
4. DEF
from the SERVICE MODE.
(4) Select
<6. TRAPEZ>
.
(5) Set the initial setting value of
<6. TRAPEZ>
.
(6) Adjust
<6. TRAPEZ>
so that the vertical lines at the
left and right edges on the screen are in parallel.
(7) Press the
[OK]
key to memorize the set values.
NTSC TRAPEZIUM PIN
(1) Receive a NTSC crosshatch signal.
(2) Follow the same step 2 to 7 as in PAL TRAPEZIUM.
CORNER PIN
Signal
generator
Remote
control unit
[4. DEF]
8. COR-UP
9. COR-LO
PAL CORNER PIN
(1) Receive a PAL crosshatch signal.
(2) Set the COMPRESS(16 : 9) to ON.
(3) Select
4. DEF
from the SERVICE MODE.
(4) Select
<8. COR-UP>
.
(5) Set the initial setting value of
<8. COR-UP>
.
(6) Select
<9. COR-LO>
.
(7) Set the initial setting value of
<9. COR-LO>
.
(8) Adjust
<8. COR-UP>
and
<9. COR-LO>
so that the
vertical lines at the four corners on the screen are
straight.
(9) Press the
[OK]
key to memorize the set values.
NTSC CORNER PIN
(1) Receive a NTSC crosshatch signal.
(2) Follow the same step 2 to 9 as in PAL CORNER PIN.
Item
Measuring
instrument
Test point
Adjustment part
Description
H. POSITION
Signal
generator
Remote
control unit
[4. DEF]
4. H-CENT
(1) Receive a PAL circle pattern signal to VIDEO-2
component terminal.
(2) Select VIDEO-2 SET from the MENU and set
VIDEO-2 SET to COMPONENT.
(3) Select
4. DEF
from the SERVICE MODE.
(4) Select
<4. H-CENT>
.
(5) Set the initial setting value of
<4. H-CENT>
.
(6) Adjust
<4. H-CENT>
to make "
C=D
".
(7) Press the
[OK]
key to memorize the set values.
Item
Measuring
instrument
Test point
Adjustment part
Description
Parallel
Straigt
C
D