1-24 (No.YA328)
V.LINEARITY
adjustment
Signal
generator
Remote
control unit
[4. DEF]
12. V-S. CR
13. V-LIN
- PAL V. LINEARITY -
(1) Receive a PAL crosshatch signal.
(2) Select
12. V-S.CR
.
(3) Set the initial setting value of
12. V-S. CR
.
(4) Select
13. V-LIN
.
(5) Set the initial setting value of
13. V-LIN
.
(6) Adjust
12. V-S. CR
and
13. V-LIN
so that the spaces
of each line on TOP, CENTRE and BOTTOM
become uniform.
- NTSC V. LINEARITY -
(1) Receive a NTSC crosshatch signal.
(2) Make similar adjustment of NTSC V-S. CR in the
same way as for "PAL V-S. CR".
H. PARALLEL
adjustment
Signal
generator
Remote
control unit
[4.DEF]
10. ANGLE
- PAL H. PARALLEL -
(1) Receive a PAL crosshatch signal.
(2) Select
10. ANGLE
.
(3) Set the initial setting value of
10. ANGLE
.
(4) Adjust
10. ANGLE
to optimize the trapezium
distortion at the centre of the screen.
- NTSC H. PARALLEL -
(1) Receive a NTSC crosshatch signal.
(2) Make similar adjustment of NTSC H. PARALLEL in
the same way as for "PAL H. PARALLEL".
H. BOW
adjustment
Signal
generator
Remote
control unit
[4.DEF]
11. BOW
- PAL H. BOW -
(1) Receive a PAL crosshatch signal.
(2) Select
11. BOW
.
(3) Set the initial setting value of
11. BOW
.
(4) Adjust
11. BOW
to optimize the horizontal arc
distortion.
- NTSC H. BOW -
(1) Receive a NTSC crosshatch signal.
(2) Make similar adjustment of NTSC H. BOW in the
same way as for "PAL H. BOW".
(3) Press the [DISPLAY] key twice to return to the
normal screen.
Item
Measuring
instrument
Test point
Adjustment part
Description
TOP
CENTRE
BOTTOM
Parallel
Straight