Item
Measuring
instrument
Test point
Adjustment part
Description
Adjustment
of
####
HOR.
POSITION
Signal
generator
Remote
control unit
2. HOR.
POSITION
10. Receive a circle pattern signal.
11. Select
2. HOR POSITION
with the MENU
▼
/
▲
key.
12. Set the initial setting value of
2. HOR. POSITION
with the
MENU - / + key.
13. Adjust
2. HOR. POSITION
to make
H=H"
as shown in Fig.3
with the MENU - / + key.
Adjustment
of VER. LIN.
& VER.
SCURVE
Signal
generator
Remote
control unit
4. VER. LINEARITY
5. VER. SCURVE
●
●
●
●
When the vertical linearity has been deteriorated
remarkably, perform the following steps.
14. Receive a cross-hatch signal.
15. Select
4. VER. LINEARITY
with the MENU
▼
/
▲
key.
16. Set the initial setting value of
4. VER LINEARITY
with the
MENU - / + key.
17. Select
5. VER. SCURVE
with the MENU
▼
/
▲
key.
18. Set the initial setting value of
5. VER. SCURVE
with the
MENU - / + key.
19. Adjust
4. VER. LINEARITY
and
5. VER. SCURVE
so that the
spaces of each line as shown in Fig.4 on
TOP
,
CENTER
and
BOTTOM
become uniform.
20. Make sure that the adjustment is properly done on the screen
of 60Hz mode.
[NOTE]
"
Adjust to make both 50Hz & 60Hz are the same v. size and
fine straight line.
"
When adjust again, adjust 50Hz mode first.
"
When adjust in 60Hz mode, only 60Hz mode is adjust.
H
H"
Fig.3
TOP
CENTER
BOTTOM