DIP Switch Setting
6.1 Micro steps Setting
The micro steps setting is in the following table, while SW1
SW2
SW3
SW4 are all on, the internal default micro steps inside is activate
this
ratio can be setting through the HISU
Dial switch
Micro steps
SW1
SW2
SW3
SW4
Default
on
on
on
on
800
off
on
on
on
1600
on
off
on
on
3200
off
off
on
on
6400
on
on
off
on
12800
off
on
off
on
25600
on
off
off
on
51200
off
off
off
on
1000
on
on
on
off
2000
off
on
on
off
4000
on
off
on
off
5000
off
off
on
off
8000
on
on
off
off
10000
off
on
off
off
20000
on
off
off
off
40000
off
off
off
off